3.2 Cleaning Procedure
Prerequisites:
Reapply a generous amount of lubricant to the O-ring when reinstalling sumps.
Procedure:
It is imperative that the entire distribution system located after the UV be chemically cleaned to ensure that the plumbing
system is free from any contaminants. This process must be performed immediately after the UV unit is installed and
repeated thereafter whenever the UV is shut down for service, without power, or inoperative for any reason. The procedure
for cleaning the plumbing system is readily accomplished as follows:
CAUTION
The sump housings will be heavy.
9
Connect the green ground
wire and red strain relief wire
to the chamber using the
grounding screw.
10
10
Align connection pins with
the lamp connector by
rotating the ring clamp.
Push the lamp connector
down onto the lamp pins and
the ring clamp pins until an
audible click is heard.
Note: Ensure the connector
is engaged on both sides.
11
11
Connect power.
Open all faucets and turn on
water supply. Inspect for any
leaks.
Note: Outlet must be
protected by a Ground Fault
Circuit Interrupter (GFCI).
1
Ensure the controller is
plugged in for entire cleaning
process.
2
Shut off the water supply.
Close each faucet.
3
Press the pressure button to
release the pressure from the
cartridges
4
Remove the drain plug at the
bottom of the sump and place
a pail to catch the water.
Reinstall the drain plug.