Owner’s Manual Models: IHS10-D4, IHS12-D4, IHS22-D4 Powered by 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com www.viqua.
Congratulations on the purchase of your ultraviolet (UV) water disinfection system! This system uses the most advanced UV technology on the market and is designed to provide you with years of trouble free operation with minimal maintenance required to protect your drinking water from microbiological contaminants. To ensure ongoing disinfection of your water, UV lamps need to be replaced annually with VIQUA factory-supplied replacements.
Safety Information Section 1 Safety Information These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment. Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any manner other than that specified in the installation manual. 1.
Safety Information WA R N I N G • During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
General Information Section 2 General Information 8 9 7 8 9 7 6 10 10 6 5 5 4 12 4 12 11 11 3 13 2 13 15 3 14 2 14 1 Figure 1 System Components Item 1 Description Sump wrench Part Number UV System WR40-50 Used on all systems. CMB-510-HF IHS12-D4, IHS10-D4 CMB-520-HF IHS22-D4 2 Sediment filter 3 O-ring OR40-50 Used on all systems. 4 Bracket - - 5 Lamp connector - Used on all systems.
General Information 2.1 Dimensions and Layout Hot water pipe 16” Clearance for lamp removal Cold water pipe Main Water Shut Off 7 Optional By-Pass Assembly 1 3 6 5 4 Optional Water Softener 25.5” Overall Length 2 MIN 4” from bottom of unit for clearance for filter changes Figure 2 System - Dimension and Layout Item 6 Description Function 1 Main water shut-off valve Allows for sampling of raw water. 2 Shut-off Valve Allows for ease of maintenance of whole home UV disinfection system.
Installation Section 3 Installation 3.1 Installing UV System CAUTION Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely fastened to ground stud on UV chamber. Prerequisites: • Determine appropriate indoor location of the controller and chamber, refer to Section 2.1. • Make sure that the controller is installed higher than the chamber and away from all water sources.
Installation 9 • Connect the green ground wire and red strain relief wire to the chamber using the grounding screw. 10 11 • Align connection pins with the lamp connector by rotating the ring clamp. • Push the lamp connector down onto the lamp pins and the ring clamp pins until an audible click is heard. • Connect power. • Open all faucets and turn on water supply. Inspect for any leaks. Note: Outlet must be protected by a Ground Fault Circuit Interrupter (GFCI).
Maintenance 6 5 BLEACH 1 1 7 Household 5.25% Bleach Solution 8 2 1 x2 x2 2 1 30 mins 2 0 1 2 • Remove the sump housings using sump wrench. • Remove cartridges and pour 2 cups of household bleach solution into the sump housings. • Reinstall the housings. Note: DO NOT use Hydrogen Peroxide. 10 9 1 15 45 2 30 • Open all faucets and turn on the cold water supply followed by hot water (if available) until you smell the bleach.
Maintenance 4.1 Replacing UV Lamp NOTICE Do not use water during replacement of UV lamp. Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 hours of continuous operation (approximately one year) in order to ensure adequate disinfection. Procedure: 1 4 3 2 1 1 2 2 10 mins 0 15 45 30 • Close all faucets and water supply. • Press the pressure button to release the pressure from the cartridges.
Maintenance 4.2 Cleaning and Replacing Quartz Sleeve Note: Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it must be replaced. Prerequisites: • Shut off water supply and drain all lines. • Depressurize the unit. Place a small pail under the unit to catch any spills. • Remove the UV lamp. Refer to Section 4.1.
Maintenance 4.3 Replacing Cartridges CAUTION The sump housings will be heavy. It is recommended to change the filter cartridges regularly, approximately 3-4 times per year depending on water quality and usage. A gradual drop in water pressure after the filtration device is an indication that the pre-filter cartridges are nearing the end of their useful life. Procedure: 4 3 2 1 10 mins 0 15 45 30 • Disconnect main power source and allow the unit to cool for 10 minutes.
Operation Section 5 Operation 5.1 Controller C 2 B 1 A Figure 3 Controller Buttons and Display Feature Description Function A Lamp timer display Counts down from 365 days to show time for annual lamp replacement. B Lamp timer reset After installing a new lamp, press and hold for five seconds to reset Lamp timer to 365. Press to silence audible alarm.
Troubleshooting Section 6 Troubleshooting Symptom Possible Cause Possible Solution GFCI and/or breaker tripped Reset GFCI and/or breaker Transient voltage surge suppressor (TVSS) damaged Replace TVSS Controller damaged Replace controller and use a TVSS GFCI or breaker repeatedly trips Connection between lamp and lamp plug is wet Clean and dry lamp pins and lamp plug, check unit for leaks or condensation Short-circuit in the electrical assembly Replace controller Leak at inlet or outlet Thr
Specifications Section 7 Specifications IHS12-D4 IHS22-D4 IHS10-D4 Maximum operating pressure 100 PSI (689 kPa) 100 PSI (689 kPa) 100 PSI (689 kPa) Minimum operating pressure 4 PSI (27.5 kPa) 4 PSI (27.5 kPa) 4 PSI (27.
Manufacturer’s Warranty Section 8 Manufacturer’s Warranty Our Commitment VIQUA is committed to ensuring your experience with our products and organization exceeds your expectations. We have manufactured your UV disinfection system to the highest quality standards and value you as our customer. Should you need any support, or have questions about your system, please contact our Technical Support team at 1.800.265.7246 or technicalsupport@viqua.com and we will be happy to assist you.
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com www.viqua.