Use and Care Manual

Installation
7
Section 3 Installation
3.1 Installing UV System
Prerequisites:
Deter
mine appropriate indoor location of the controller and chamber, refer to Section 2.1.
M
ake sure that the controller is installed higher than the chamber and away from all water sources.
Ensu
re adequate clearance above chamber to allow for removal of the lamp and sleeve.
Make s
ure to turn off the main water supply.
Ma
ke all necessary plumbing connections refer to Section 2.1.
Procedure:
1
Install the UV system on the
wall using lag bolts (not
supplied). Mounting holes are
located in the metal bracket.
2
Slide controller onto mounting
bracket.
3
Insert the reference card
between controller and
mounting bracket.
4
Connect power cord to
controller.
DO NOT connect the power
cord to the GFCI outlet at this
time.
5
Place O-ring on the sleeve as
shown. Insert the sleeve into
the chamber as shown in
step 6.
6
Ensure quartz sleeve is
properly centered in the
chamber.
7
2
1
Place sleeve bolt onto the
quartz sleeve, carefully push
down and hand tighten onto
chamber.
8
2
1
Insert lamp into the quartz
sleeve and thread into sleeve
bolt until hard stop.
CAUTION
Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely
fastened to ground stud on UV chamber.