Product Brochure
Specifications
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. 1.519.763.1032 • f. 1.519.763.5069 • tf. 1.800.265.7246 (US /CAN) • t. +31.73.747.0144 (EUR) • info@viqua.com • www.viqua.com
LIT-520331-R_RevA © 2016 VIQUA - a Trojan Technologies Business
MODEL IHS12-D4 IHS22-D4
FLOW RATES
US Public Health (16 mJ/cm
2
) -- --
VIQUA Standard (30 mJ/cm
2
)
12 GPM (45 lpm)
(2.7 m
3
/hr)
12 GPM (45 lpm)
(2.7 m
3
/hr)
NSF/EPA (40 mJ/cm
2
)
9 GPM (34 lpm)
(2 m
3
/hr)
9 GPM (34 lpm)
(2 m
3
/hr)
DIMENSIONS
Dimensions 25.5” x 12” x 28” (64 cm x 30 cm x 70 cm) 25.5” x 12” x 28” (64 cm x 30 cm x 70 cm)
Inlet/Outlet Port Size 3/4” FNPT/MNPT 3/4” FNPT/MNPT
Shipping Weight 35 lbs (15.9 kg) 35 lbs (15.9 kg)
ELECTRICAL
Voltage 100-240V / 50-60 Hz 100-240V / 50-60 Hz
Power Consumption 50 W 50 W
Maximum Operating Pressure 125 psi (8.62 bar) 125 psi (8.62 bar)
Ambient Water Temperature 2-40°C (36-104°F) 2-40°C (36-104°F)
FEATURES
Visual “Power On” YES YES
Chamber Material 304 SS 304 SS
Visual Lamp Life Remaining YES YES
Audible Lamp Failure YES YES
Audible Lamp Replacement
Reminder
YES YES
High-flow Sediment Filter 10” 20”
High-performance Carbon Filter 20” 20”
Replacement Parts
602805 – UV lamp for IHS12-D4 and IHS22-D4
602732 – quartz sleeve for IHS12-D4 and IHS22-D4
650713-013 – power supply for IHS12-D4 and IHS22-D4
CMB-510-HF – dirt/rust cartridge for IHS12-D4
CMB-520-HF – dirt/rust cartridge for IHS22-D4
C2-02 – taste/odour cartridge for IHS12-D4 and IHS22-D4
Fluence Rate (mJ/cm
2
)
Flow Rate (USGPM)
0
10
20
30
40
50
60
70
80
90
100
0 5 10 15 20 25 30
IHS12-D4 & IHS22-D4 DOSE CURVES
IHS12-D4 &
IHS22-D4