Instructions / Assembly

Specifications
18
8.2 Home and Professional - Plus
Visual Lamp Life
Remaining
Yes Yes Yes Yes
Total Running Time Yes Yes Yes Yes
Chamber Material 304 SS 304 SS 304 SS 304 SS
1
Units ending in “/2B” have BSPT connections.
2
Units ending in “/2” are for 230V applications.
Model VH410M VP600M VP950M
Flow Rate
US Public Health 16 mJ/
cm
2
@ 95% UVT
34 gpm (130 lpm) (7.8 m
3
/hr) 40 gpm (151 lpm) (9.1 m
3
/hr) 60 gpm (230 lpm) (13.7 m
3
/hr)
VIQUA Standard 30 mJ/
cm
2
@ 95% UVT
18 gpm (70 lpm) (4.2 m
3
/hr) 30 gpm (113 lpm) (6.7 m
3
/hr) 46 gpm (175 lpm) (10.5 m
3
/hr
NSF/EPA 40mJ/cm
2
@
95% UVT
14 gpm (54 lpm) (3.3 m
3
/hr) 22 gpm (83 lpm) (5.0 m
3
/hr) 35 gpm (133 lpm) (8.0 m
3
/hr)
Dimensions
Chamber 57.9 cm x 8.9 cm (22.8” x 3.5”) 78 cm x 8.9 cm (30.7” x 3.5”) 114 cm x 8.9 cm (45.0” x 3.5”)
Controller 100-250 VAC
22.3 cm x 8.1 cm x 6.4 cm
(8.8” x 3.2” x 2.5”)
22.3 cm x 8.1 cm x 6.4 cm
(8.8” x 3.2” x 2.5”)
22.3 cm x 8.1 cm x 6.4 cm
(8.8” x 3.2” x 2.5”)
Inlet/Outlet Port Size
1
Combo 3/4” FNPT/1” MNPT 1” MNPT 1.5” MNPT
Shipping Weight 7.7 kg (17 lbs) 8.6 kg (19 lbs) 13.1 kg (29 lbs)
Electrical
Voltage
2
120-240 V / 50/60 Hz 120-240 V / 50/60 Hz 120-240 V / 50/60 Hz
Max. Current 2.5 Amp 2.5 Amp 2.5 Amp
Power Consumption 60 W 78 W 110 W
Lamp Watts 46 W 58 W 90 W
Maximum Operating Pressure 125 psi (861 kPa) 125 psi (861 kPa) 125 psi (861 kPa)
Minimum Operating Pressure 15 psi (103 kPa) 15 psi (103 kPa) 15 psi (103 kPa)
Ambient Water Temperature 2-40 ºC (36-104 ºF) 2-40 ºC (36-104 ºF) 2-40 ºC (36-104 ºF)
Lamp Type Sterilume™-HO (high-output) Sterilume™-HO (high-output) Sterilume™-HO (high-output)
Visual “Power-On” Yes Yes Yes
Audible Lamp Failure Yes Yes Yes
Lamp Replacement Reminder Yes Yes Yes
Visual Lamp Life Remaining Yes Yes Yes
Total Running Time Yes Yes Yes
254nm UV Monitor Yes Yes Yes
Chamber Material 304 SS 304 SS 304 SS
Solenoid Output Yes Yes Yes
4-20 mA Output Yes (Optional 260134) Yes (Optional 260134) Yes (Optional 260134)
1
Units ending in “2B” have BSPT connections.
2
Units ending in “/2” are for 230V applications.
Model VH200 VH410 VP600 VP950