Instructions / Assembly

Maintenance
3
Section 2 Maintenance
2.1 Replacing UV Lamp
The amount of UV light created by the UV lamp decreases over time, requiring that the UV lamp be replaced. The system
will automatically notify you when it is time to replace the UV lamp.
Note: Not applicable to TAP systems.
Procedure:
WARNING
Always disconnect power before performing any work on the disinfection system.
Always shut-off water flow and release water pressure before servicing.
Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.
Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
NOTICE
Do not use water during replacement of UV lamp.
1
1
2
Close main water supply to
the UV System, and then
open a tap downstream of the
UV System to release
pressure.
2
0
30
15
45
10 mins
Disconnect main power
source and allow the unit to
cool for 10 minutes.
Note: Ensure there is no
other power source
connected such as, Solenoid
Junction Box.
3
1
2
1
2
UV
Remove the UV lamp
connector.
Note: Follow illustration that
shows your specific
connector.
Remove the UV lamp.
5
Re-insert the new UV lamp
inside the quartz sleeve.
Attach the connector to the
UV lamp and note that the
connector will only allow
correct installation in one
position.
6
1
2
Place and tighten the UV
lamp connector.
Follow illustration that shows
your specific connector.
1919
7
Plug the unit back to the
power source. Reset the end
of lamp timer alarm back to
365 days.
Note: Not applicable to TAP
systems.
Open the inlet valve slowly.
8
Close the downstream tap
once the UV chamber is filled
with water, and inspect for
any leakages.