Instructions / Assembly
Manufacturer’s Dose Flow Chart
14
Section 7 Manufacturer’s Dose Flow Chart
Section 8 Specifications: Standard and Validated
Model S1Q-PA
S2Q-P/12VDC/
S2Q-PA
S5Q-P/12VDC/
S5Q-PA/SV5Q-PA
*
S8Q-PA/
SV8Q-PA
*
Flow Rate
*NSF Class B Certified
16mJ/cm
2
@ 70% UVT
--
3.6 gpm (13.6 lpm) (0.8 m
3
/
hr)
7 gpm (26.5 lpm) (1.6 m
3
/
hr)
US Public Health 16mJ/cm
2
@ 95% UVT
3.5 gpm (13 lpm) (0.8 m
3
/
hr)
5 gpm (19 lpm) (1.1 m
3
/hr) 11 gpm (42 lpm) (2.5 m
3
/hr) 20 gpm (75 lpm) (4.5 m
3
/hr)
VIQUA Standard 30 mJ/cm
2
@ 95% UVT
2 gpm (7 lpm) (0.4 m
3
/hr) 3 gpm (11 lpm) (0.7 m
3
/hr) 6 gpm (23 lpm) (1.4 m
3
/hr) 10 gpm (38 lpm) (2.3 m
3
/hr)
NSF/EPA 40mJ/cm
2
@ 95%
UVT
1.5 gpm (5 lpm) (0.3 m
3
/hr) 2 gpm (7 lpm) (0.4 m
3
/hr)
4.5 gpm (17 lpm) (1.0 m
3
/
hr)
8 gpm (29 lpm) (1.8 m
3
/hr)
Dimensions
Chamber 38.1 x 6.4 cm (15" x 2.5")
43.2 cm x 6.4 cm (17” x
2.5”)
56 cm x 6.4 cm (22” x 2.5”) 90 cm x 6.4 cm (35” x 2.5”)
Controller 100-250 VAC
18.6 cm x 8.1 cm x 6.4 cm
(7.3” x 3.2” x 2.5”)
18.6 cm x 8.1 cm x 6.4 cm
(7.3” x 3.2” x 2.5”)
18.6 cm x 8.1 cm x 6.4 cm
(7.3” x 3.2” x 2.5”)
18.6 cm x 8.1 cm x 6.4 cm
(7.3” x 3.2” x 2.5”)
Controller 12 VDC -
13.5 cm x 4.3 cm x 5.8 cm
(5.3” x 1.7” x 2.3”)
13.5 cm x 4.3 cm x 5.8 cm
(5.3” x 1.7” x 2.3”)
-
Inlet/Outlet Port Size
1
1/4” MNPT 1/2” MNPT 3/4” MNPT” 3/4” MNPT
Shipping Weight 2.7 kg (6 lbs) 2.7 kg (6 lbs) 2.7 kg (6 lbs) 4.5 kg (10 lbs)
Electrical
Voltage
2
100-240 V /50/60 Hz
100-240 V /
50/60 Hz
12 VDC
100-240 V /
50/60 Hz
12 VDC 100-240 V / 50/60 Hz
Max. Current 0.6 Amp 0.6 Amp 1.8 Amp 0.6 Amp 1.8 Amp 0.6 Amp
Power Consumption 19 W 22 W 20 W 30 W 27 W 46 W
UV lamp Watts 14 W 17 W 15 W 25 W 20 W 37 W
Maximum Operating Pressure 125 psi (861 kPa) 125 psi (861 kPa) 125psi (861 kPa) 125 psi (861 kPa)
Minimum Operating Pressure 15 psi (103 kPa) 15 psi (103 kPa) 15psi (103 kPa) 15 psi (103 kPa)
Ambient Water Temperature 2-40 ºC (36-104 ºF) 2-40 ºC (36-104 ºF) 2-40 ºC (36-104 ºF) 2-40 ºC (36-104 ºF)
UV Lamp Type
Sterilume™-EX
(rendimiento estándar)
Sterilume™-EX (standard-
output)
Sterilume™-EX (standard-
output)
Sterilume™-EX (standard-
output)
UV Chamber Material 304 SS 304 SS 304 SS 304 SS
1
Units ending in “/2B” have BSPT connections.
2
Units ending in “/2” are for 230V applications.