Full Product Manual

Maintenance
13
4. Discard the used cartridge and clean the sump housing as required. Make sure to thoroughly rinse the sump with water
to remove
any cleaning agents.Before installing a new cartridge, please ensure that the o-ring seals are properly
seated
on
the shoulders at the top of the sump (Refer to Figure 7), if there is any visible damage on the o-rings please repl
ace
them (P/N
: OR40-50).
5. Ensure o-rings are liberally coated with a silicone based lubricant.
6. Install the new cartridge in the reverse procedure as stated above turning the collar clockwise until the sump is tight.
Note: Do not over tighten.
7. Plug UV unit into the Ground Fault Circuit Interrupter (GFCI) outlet and power-up the system.
8. Slowly turn on the water supply and allow any air that may now be present to bleed off by
depressing pressure relief
button
on top of the sump until air is purged from filter. Now you are ready to return the system to use.
Figure 7 O-ring on Sump