Specifications
17
Section 8 Specifications
8.1 Standard and Validated
Model VH200-F10 VH410-F20
Flow Rate
US Public Health 16 mJ/cm
2
16 GPM (60 lpm) (3.6 m
3
/hr) 34 GPM (130 lpm) (7.8 m
3
/hr)
VIQUA Standard 30 mJ/cm
2
9 GPM (34 lpm) (2.0 m
3
/hr) 18 GPM (70 lpm) (4.2 m
3
/hr)
NSF/EPA 40 mJ/cm
2
7 GPM (26 lpm) (1.6 m
3
/hr) 14 GPM (54 lpm) (3.3 m
3
/hr)
Overall Dimensions (width x depth x height) 17”x 10.5” x 17.8” 17" x 10" x 29"
Inlet/Outlet Port Size 1“FNPT/Combo 3/4“FNPT & 1“MNPT 3/4” FNPT
Shipping Weight 10.5 kg (23 lbs) 13.2 kg (29 lbs)
Electrical
Voltage 100-240 V/ 50/60 Hz 100-240 V/ 50/60 Hz
Max. Current 1.5 Amp 1.5 Amp
Power Consumption 35 W 60W
Lamp Watts 27 W 45W
Maximum Operating Pressure 100 psi (689 kPa) 100 psi (689 kPa)
Minimum Operating Pressure 15 psi (103 kPa) 15 psi (103 kPa)
Ambient Water Temperature 2-40
qC (36-104 qF) 2-40 qC (36-104 qF)
UV Lamp Type Sterilume
™
- HO (high output) Sterilume
™
- HO (high output)
Visual “Power-On” Yes Yes
Audible Lamp Failure Yes Yes
Lamp Replacement Reminder Yes Yes
Visual Lamp Life Remaining Yes Yes
Total Running Time Yes Yes
254 nm UV Monitor No No
Solenoid Output (solenoid not incl.) No No
Chamber Material 304 SS 304 SS
Filter Housing 10” high flow 20” high flow