Use and Care Manual

Installation
10
Procedure:
1
2
3
1
Disconnect the controller then
disconnect the UV sensor
from blue jack.
Reconnect the controller with
out UV sensor.
2
2
1
2
2
2
Shut off the water supply.
Open an upstream faucet to
release line pressure
3
Press the pressure button to
release the pressure from the
cartridges.
4
Remove filter housing(s)
using sump wrench.
5
Household 5.25%
Bleach Solution
BLEACH
x2
2
1
Remove cartridge(s) and
pour 2 cups of household
bleach solution into the filter
housing(s).
Note: DO NOT use Hydrogen
Peroxide.
6
Connect only the filter
housing(s) to the unit.
7
Open each faucets and turn
on water supply.
Allow water to fill the
chamber.
8
0
30
15
45
30 mins
Turn on the cold water supply
followed by hot water (if
available) until you smell the
bleach.
Close all faucets and allow
bleach to settle in the water
lines for 30 minutes.
9
With all faucets closed,
remove filter housing(s)
using sump wrench.
1010
1
2
Reinstall the cartridge(s) into
filter housing(s) and connect
to the unit.
Flush all water outlets until
bleach can no longer be
smelled (at least 5 minutes).
11
Press the pressure button to
purge air and to complete the
disinfection procedure.
1212
2
3
1
Disconnect the controller then
connect the UV sensor from
blue jack.
Reconnect the controller.