Use and Care Manual
Maintenance
11
Section 4 Maintenance
4.1 Replacing UV Lamp
UV lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after
18000 hours of continuous operation (approximately two years) in order to ensure adequate disinfection.
Procedure:
WARNING
• Always disconnect power before performing any work on the disinfection system.
• Always shut-off water flow and release water pressure before servicing.
• Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.
• Replace the UV lamp biennially to ensure maximum disinfection.
• Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
NOTICE
Do not use water during replacement of UV lamp.
1
1
1
2
• Close all faucets and water
supply.
• Press the pressure button to
release the pressure from the
cartridges.
2
0
30
15
45
10 mins
• Disconnect main power
source and allow the unit to
power down for 10 minutes.
3
• Drain the water from the UV
system.
• Close the water inlet after the
water is drained.
4
• Pinch wire form to release the
lamp connector.
5
• Remove the lamp connector.
6
Hg
UV
2
1
• Rotate and remove the UV
lamp from the sleeve.
7
2
1
Hg
UV
• Install and rotate the lamp
into the sleeve assembly.
Ensure to rotate the lamp
completely.
Note: Do not touch glass
with bare hands.
8
• Reinstall the lamp connector.