Section 4 Maintenance
4.1 Replacing UV Lamp
UV lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after
18000 hours of continuous operation (approximately two years) in order to ensure adequate disinfection.
Procedure:
WARNING
Always disconnect power before performing any work on the disinfection system.
Always shut-off water flow and release water pressure before servicing.
Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.
Replace the UV lamp biennially to ensure maximum disinfection.
Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
NOTICE
Do not use water during replacement of UV lamp.
1
1
1
2
Close all faucets and water
supply.
Press the pressure button to
release the pressure from the
cartridges.
2
0
30
15
45
10 mins
Disconnect main power
source and allow the unit to
power down for 10 minutes.
3
Drain the water from the UV
system.
Close the water inlet after the
water is drained.
4
Pinch wire form to release the
lamp connector.
5
Remove the lamp connector.
6
Hg
UV
2
1
Rotate and remove the UV
lamp from the sleeve.
7
2
1
Hg
UV
Install and rotate the lamp
into the sleeve assembly.
Ensure to rotate the lamp
completely.
Note: Do not touch glass
with bare hands.
8
Reinstall the lamp connector.