Use and Care Manual

Maintenance
13
Note: After replacing the UV lamp or sleeve perform the disinfection procedure, refer to Section 3.2.
5
Remove the sleeve.
6
Remove O-ring from top of
the sleeve.
Remove O-ring from bottom
of the chamber (it may fall
during sleeve removal
process).
7
Mild
Acid
Clean the sleeve with a cloth
soaked in CLR, vinegar or
some other mild acid and
then rinse with water.
Note: If sleeve cannot be
cleaned completely or it is
scratched or cracked, then
replace the sleeve.
8
3
1
2
Connect the sleeve bolt at the
bottom of the sleeve
assembly.
9
Reinstall the sleeve with
arrow pointing up.
Note: DO NOT rotate sleeve
and touch glass with bare
hands.
1010
Reinstall the new lubricated
O-rings over the top end of
the sleeve.
1111
2
1
Connect the sleeve bolt to the
top of the sleeve assembly.
12
12
1
2
Remove the sleeve bolt at the
bottom of the sleeve
assembly.
1313
Reinstall the O-ring at the
bottom of the sleeve.
1414
3
2
1
Connect the sleeve bolt at the
bottom.
When service is complete,
assemble the prerequisites in
the reverse order of
disassembly.