INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Viron P280 eVo Viron P300 eVo Viron Cartridge Viron P600 eVo Pool and Spa Pumps Filter Bolero ND Cleaner INSTALLATION AND OPERATING INSTRUCTIONS Viron P280 eVo Viron P300 eVo Viron P600 eVo Melbourne: 03 8796 8600 Sydney: 02 9853 2100 Brisbane:16/01/2012 07 3308 5400 Gold Coast: 07 5552 2600 Townsville: 07 4750 3100 Adelaide: 08 8152 7600 Perth: 08 9350 2600 sales@astralpool.com.au www.astralpool.com.
Inst.
SERIOUS INJURY OR DEATH MAY OCCUR IF THIS PRODUCT IS NOT USED, OPERATED OR INSTALLED ACCORDING TO THESE INSTRUCTIONS AND RELEVANT AUSTRALIAN STANDARDS. THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS. PLEASE ENSURE YOUNG CHILDREN ARE SUPERVISED SO THAT THEY DO NOT PLAY WITH THE APPLIANCE. PUMP PRODUCES HIGH PRESSURES – STAND CLEAR OF PUMP AND ALL FILTRATION EQUIPMENT DURING START UP PUMP MUST ONLY BE INSTALLED BY A QUALIFIED POOL INDUSTRY PROFESSIONAL.
GENERAL The Viron EVO Pool Pump is a unique variable-speed permanent magnet DC motor combined with an energy efficient pump wet end. When installed and plumbed correctly, the Viron EVO will significantly reduce operating costs, lower noise levels and reduce greenhouse emissions.
INSTALLATION This appliance must be installed by a trained pool professional service technician. When installing the appliance, ensure all parts are installed in the correct zone in accordance with the wiring rules. In particular refer to AS/NZS 3000 (Australia) and EN 60364 (EU). A. Plan position of pump so that it will be: 1. 2. Free of water flooding, such as in a sump, garden hollow, ditch or at bottom of bank with run off.
OPERATION 1. Prime pump if hair and lint pot is dry as follows – Close off valve on suction line if present. Remove lint pot lid. Fill lint pot and chamber with water. Replace and secure lint pot lid and seal. 2. Open all valves, allowing water to flow through pump. 3. Switch on power to pump, motor to start. 4. If some flow of water does not establish within on half minute, switch off and prime pump again. If pump does not prime within 3 attempts, check all suction connections for sealing.
the infloor cleaning system. Other special purpose flow rates may include but are not limited to: operating spa jets, operating water falls or water features, operating a suction pool cleaner. High Speed is generally set up to backwash your sand filter. As a rule of thumb, this speed should be set so that the gauge on your filter is approximately 70kPa to 100 kPa in pressure but this will depend on the size of your filter, and the size and length of the backwash pipe line.
OPERATION OF CONTROL PANEL – VIRON P280 AND P300 EVO Viron P280 eVo and P300 eVo Buttons and their functions: - On/Off Button: For toggling between On and Off state. When the pump is in On state, the On/Off LED is on. In Off state, the LED is off. The pump will remember On/Off state. When the pump is turned on, it will auto-prime for 5 minutes at Speed 3 before entering the pre-set speed level. - Low Speed Button: For switching to pre-set Speed Level 1.
Startup: When power is on, if the pump is in Off state, it will stand by. When power is on, if the pump is in On state, it will auto-prime for 5 minutes at High Speed. While auto-priming the factory preset Speed LED will be on and Speed 3 LED will keep flashing until auto-priming process is finished. After auto-priming the pump will enter the factory preset Speed Level. Fault LED: (in red) When the pump is running, if warning condition is true, it will enter warning state.
OPERATION OF CONTROL PANEL – VIRON P600 EVO (CONT…) Using the in built timer to operate pump with an AstralPool Chlorinator or RolaChem dosing unit Factory Default Setting 1. The inbuilt timers are activated and will control the time the pump operates 2. Connectivity to AstralPool compliant Salt Chlorinators, RolaChem Chemical dosing controllers or Viron Connect remote Controls is turned “off” 3. Use the “auto” button to turn the pump on or off.
5. 6. 7. 8. Press and HOLD “enter” for 3 seconds Toggle Menu until “TMR” appears. Press UP or Down buttons to turn “TMR OFF” Press “enter” to accept 9. Press “auto” to return to main menu. 10. When cycling through the Menu button TMR will no longer appear 11. You will no longer be able to automatically have the speed of the pump changed during different times opf the day. 12.
Data cable connector: If a compatible AstralPool VX Salt Chlorinator, Viron Salt Chlorinator or Viron Connect Touch Screen, is connected with the AstralPool communication cable, the speed of the pump and operating hours can be controlled by these devices. The Viron P600 eVo must have its inbuilt timer deactivated if the pump operating times and speeds are to be operated by the compatible AstralPool Salt Chlorinator, RolaChem Dosing Controller or Viron Connect remote touch screen.
• All model Viron eVo pumps and compatible VX Timer model chlorinator or Viron Salt Chlorinator • Timer periods set up in chlorinator • Low, medium or high speed can be selected for each timer period • Data cable connecting pump to chlorinator via comms interface module • P600 Pump to be set up with timer periods deactivated • Pump speed can be changed from pump (from chlorinator early 2012) Comms Power Supply Transfomer • 240v power 24v data All model Viron eVo pumps, VX S (non timer) model chlorinato
SPEED SELECTION EXAMPLES FOR VIRON P600 EVO Function Vacuuming Pool or Spa Operating Spa Jets Operating Waterfall or Water Feature Cleaning up pool with Cloudy Water General Filtration Single Pump Infloor Cleaning System Compatible Pressure Cleaner Speed Medium Speed (high speed may collapse vacuum hose) Medium or High Speed Medium Speed or High Speed, depending on effect required Up to 24 hours on High Speed Low Speed (8 hours in winter, 8 to 12 hours in summer) Medium Speed for 3 to 3 hours per day and l
MAINTENANCE Maintenance Schedule: You new product incorporates moving parts and withstands high velocity water with chemicals in it. Some of these parts will wear in the normal course of use and require regular checks and maintenance. Performing these checks and maintenance will identify parts that have worn and require repair/replacement before further serious damage is sustained. A small amount of regular care and attention to your pool equipment will help ensure long life and trouble free performance.
Inst.
WARRANTY AstralPool Australia Pty Ltd (ABN 97 007 284 504) ("AstralPool") provides the following warranty in relation to its Viron eVo series Pool and Spa pumps ("Product"). Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
Exclusions The warranty will not apply where: (a) the customer is in breach of the Terms and Conditions of Sale; (b) the Product was used for a purpose other than one it was intended for; (c) the Product was repaired, modified or altered by any person other than AstralPool; (d) the Product has not been installed, maintained and/or operated in complete compliance with the installation and operating instructions and any instructions by AstralPool; (e) the Product has been subject to accident, negligence, alte
Astral Pool reserves the right to repair or replace defective components or products at its sole discretion. Astral Pool shall have no liability for incidental or consequential damages or delays caused either directly or indirectly by any malfunction of or defect of or failure of the equipment.
INSTALLATION INSTALLATION AND AND OPERATING OPERATING INSTRUCTIONS INSTRUCTIONS II INSTALLATION INSTALLATION AND AND OPERATING OPERATING INSTRUCTIONS INSTRUCTIONS ASTRALPOOL Pty. Limited. A.B.N. 97 007 284 504 www.astralpool.com.au email: service@astralpool.com.au Information and specifications subject to change without notice. Victoria: Ph: (03) 8796 8600 Fax: (03) 8796 8670 New South Wales: Ph: (02) 9853 2100 Fax: (02) 98532170 Queensland: Ph: (07) 3308 5400 Fax: (07) 3308 5470 Inst.