Datasheet

Document Number: 40015
Revision 13-Jun-02
www.vishay.com
10
150D
Vishay Sprague
For technical questions, contact tantalum@vishay.com
DIMENSIONS in inches [millimeters]
LEAD SIZEWITH INSULATING SLEEVE*
CASE
CODE
A
B
R
S
AWG
NO.
24
24
22
22
NOMINAL
DIAMETER
0.020
[0.51]
0.020
[0.51]
0.025
[0.64]
0.025
[0.64]
*When a shrink-fitted insulation is used, it shall lap over the ends of the capacitor body.
L
0.286 ± 0.031
[7.26 ± 0.79]
0.474 ± 0.031
[12.04 ± 0.79]
0.686 ± 0.031
[17.42 ± 0.79]
0.786 ± 0.031
[19.96 ± 0.79]
D
0.135 ± 0.016
[3.43 ± 0.41]
0.185 ± 0.016
[4.70 ± 0.41]
0.289 ± 0.016
[7.34 ± 0.41]
0.351 ± 0.016
[8.92 ± 0.41]
J (MAXIMUM)
0.422
[10.720]
0.610
[15.490]
0.822
[20.880]
0.922
[23.420]
PERFORMANCE CHARACTERISTICS
Operating Temperature: - 55°C to + 85°C. (To + 125°C
with voltage derating.)
Capacitance Tolerance: At 120 Hz, + 25°C. ± 20%,
± 10% standard. ± 5% available as special.
Dissipation Factor: At 120 Hz, + 25°C. Dissipation factor, as
determined from the expression 2πfRC, shall not exceed the
values listed in the Standard Ratings Tables.
DC Leakage Current (DCL Max.):
At + 25
°C: Leakage current shall not exceed the values listed
in he Standard Ratings Tables.
0.047 [1.19] MAX.
0.125 [3.18] MAX.
SOLID TINNED
NICKEL LEADS
1.500 ± 0.250
[38.10 ± 6.35]
L
J
MAX.
1.500 ± 0.250
[38.10 ± 6.35]
D
DIA.
Solid-Electrolyte TANTALEX
®
Capacitors
Hermetically-Sealed, Axial-Lead
FEATURES
These high performance, hermetically-sealed TANTALEX
®
capacitors have set the standard for solid-electrolyte
tantalum capacitors for more than three decades.
High capacitance, low DCL, low dissipation factor and
exceptional operating stability.
Performance and reliability have been proven in
commercial, industrial and military applications.
Available in four case codes and capacitors and are
supplied with plastic-film insulation.
Terminals are solid, tinned nickel wire leads.
The Military equivalent to the 150D is the CSR13 which is
qualified to MIL-C-39003/01.
At + 85
°C: Leakage current shall not exceed 10 times the
values listed in the Standard Ratings Tables.
At +125
°C: Leakage shall not exceed 15 times the values
listed in the Standard Ratings Tables.
Life Test: Capacitors shall withstand rated DC
voltage applied at + 85°C for 2000 hours or derated DC
voltage applied at + 125°C for 1000 hours.
Following the life test:
1. DCL shall not exceed 125% of the initial requirement.
2. Dissipation Factor shall meet the initial requirement.
3. Change in capacitance shall not exceed ± 5%.

Summary of content (10 pages)