Datasheet

2003 Feb 25 19
BCcomponents Product specification
Aluminum electrolytic capacitors
Axial Standard Miniature
021 ASM
SPECIFIC TESTS AND REQUIREMENTS
General tests and requirements are specified in data handbook BC01, section “Tests and Requirements”.
Table 6 Test procedures and requirements
TEST
PROCEDURE
(quick reference)
REQUIREMENTS
NAME OF TEST REFERENCE
Endurance IEC 60 384-4/
EN130 300
subclause 4.13
T
amb
= 85 °C; U
R
applied;
case ÆD ´ L = 4.5 ´ 10 to 10 ´ 25 mm:
U
R
= 6.3 to 25 V: 1 000 hours;
U
R
= 40 to 100 V: 2 000 hours;
case ÆD ´ L = 10 ´ 30 to 21 ´ 38 mm:
U
R
= 6.3 to 100 V: 5 000 hours
U
R
£ 6.3 V; DC/C: +15/-30%
U
R
> 6.3 V; DC/C: ±15%
tan d £ 1.3 ´ spec. limit
Z £ 2 ´ spec. limit
I
L5
£ spec. limit
T
amb
= 105 °C; U
R
applied;
case ÆD ´ L = 10 ´ 30 to 21 ´ 38 mm:
1 500 hours
DC/C: £ ±15%
tan d £ 1.6 ´ spec. limit
Z £ 2 ´ spec. limit
I
L5
£ spec. limit
Useful life CECC 30 301
subclause 1.8.1
T
amb
= 85 °C; U
R
and I
R
applied;
case ÆD ´ L = 4.5 ´ 10 to 10 ´ 25 mm:
2
500 hours;
case ÆD ´ L = 10 ´ 30 to 21 ´ 38 mm:
8
000 hours
U
R
£ 6.3 V; DC/C: +45/-50%
U
R
> 6.3 V; DC/C: ±45%
tan d £ 3 ´ spec. limit
Z £ 3 ´ spec. limit
I
L5
£ spec. limit
no short or open circuit
total failure percentage: £1%
Shelf life
(storage at
high temperature)
IEC 60 384-4/
EN130 300
subclause 4.17
T
amb
= 85 °C; no voltage applied;
500 hours
after test: U
R
to be applied for 30 minutes,
24
to 48 hours before measurement
DC/C, tan d, Z:
for requirements
see ‘Endurance test’ above
I
L5
£ 2 ´ spec. limit