Datasheet

Professional Leaded Resistors
MBA/SMA 0204, MBB/SMA 0207, MBE/SMA 0414 - Professional
Vishay Beyschlag
www.vishay.com For technical questions, contact: ff3cresistors@vishay.com Document Number: 28766
22 Revision: 28-Aug-07
DESCRIPTION
MBA/SMA 0204, MBB/SMA 0207 and MBE/SMA 0414
professional leaded thin film resistors are the general
purpose resistor for all fields of professional electronics
where reliability and stability is of major concern. Typical
applications include industrial, telecommunication and
medical equipment.
FEATURES
Approved according to CECC 40101-806
Advanced thin film technology
Power dissipation rating up to 1 W
Excellent overall stability: class 0.25
Wide professional range: 0.22 Ω to 22 MΩ
Lead (Pb)-free solder contacts
Pure tin plating provides compatibility with lead (Pb)-free
and lead containing soldering processes
Compatible with “Restriction of the use of Hazardous
Substances” (RoHS) directive 2002/95/EC (issue 2004)
APPLICATIONS
Industrial
Telecommunication
Medical equipment
Note:
MB_ series has been merged with the related SMA series to form one series “MB_/SMA__”.
METRIC SIZE
DIN: 0204 0207 0414
CECC: A B D
TECHNICAL SPECIFICATIONS
DESCRIPTION MBA/SMA 0204 MBB/SMA 0207 MBE/SMA 0414
CECC size A B D
Resistance range 0.22 Ω to 10 MΩ 0.22 Ω to 22 MΩ 0.22 Ω to 22 MΩ
Resistance tolerance ± 5 %; ± 1 %; ± 0.5 %
Temperature coefficient ± 50 ppm/K; ± 25 ppm/K
Operation mode long term standard long term standard long term standard
Climatic category (LCT/UCT/days) 55/125/56 55/155/56 55/125/56 55/155/56 55/125/56 55/155/56
Rated dissipation, P
70
0.25 W 0.4 W 0.4 W 0.6 W 0.65 W 1.0 W
Operating voltage, U
max
AC/DC 200 V 350 V 500 V
Film temperature 125 °C 155 °C 125 °C 155 °C 125 °C155°C
Max. resistance change at P
70
for resistance range, ΔR/R max., after:
1 Ω to 332 kΩ 1 Ω to 1 MΩ 1 Ω to 2.4 MΩ
1000 h 0.25 % 0.5 % 0.25 % 0.5 % 0.2 % 0.4 %
8000 h 0.5 % 1.0 % 0.5 % 1.0 % 0.4 % 0.8 %
225 000 h 1.5 % - 1.5 % - 1.2 % -
Specified lifetime 225 000 h 8000 h 225 000 h 8000 h 225 000 h 8000 h
Permissible voltage against ambient:
1 minute 300 V 500 V 800 V
continuous 75 V 75 V 75 V
Failure rate 0.7 x 10
-9
/h 0.3 x 10
-9
/h 0.1 x 10
-9
/h

Summary of content (11 pages)