Datasheet

PR01/02/03
www.vishay.com
Vishay BCcomponents
Revision: 24-Jun-13
14
Document Number: 28729
For technical questions, contact: filmresistorsleaded@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
4.7
Voltage proof on
insulation
Maximum voltage U
RMS
= 500V
during 1min; metal block method
No breakdown or flashover
4.16
Robustness of
terminations:
4.16.2 21 (Ua1) Tensile all samples Load 10N;10s
Number of failures:
< 1 x10
-6
4.16.3 21 (Ub)
Bending half
number of samples
Load 5N;4x90°
Number of failures:
< 1 x10
-6
4.16.4 21 (Uc)
Torsion other half
of samples
3 x360° in opposite directions
No damage
R
max.
:± (0.5 %R +0.05)
4.20 29 (Eb) Bump 3x1500bumps in three directions; 40g
No damage
R
max.
:± (0.5 %R +0.05)
4.22 6 (Fc) Vibration
Frequency 10Hz to500Hz;
displacement 1.5mm or acceleration 10g;
three directions; total 6h (3 x2h)
No damage
R
max.
:± (0.5 %R +0.05)
4.19 14 (Na)
Rapid change of
temperature
30min at LCT and
30min at UCT; 5cycles
No visual damage
PR01: R
max.
:± (1 %R +0.05
PR02: R
max.
:± (1 %R +0.05
PR03: R
max.
:± (2 %R +0.05
4.23 Climatic sequence:
4.23.2 2 (Ba) Dry heat 16 h; 155 °C
4.23.3 30 (Db)
Damp heat
(accelerated)
1
st
cycle
24 h; 55 °C; 90 % to 100 % RH
4.23.4 1 (Aa) Cold 2 h; - 55 °C
4.23.5 13 (M) Low air pressure 2 h; 8.5 kPa; 15 °C to 35 °C
4.23.6 30 (Db)
Damp heat
(accelerated)
remaining cycles
5days;55°C; 95% to100 %RH
R
ins min.
: 10
3
M
R
max.
: ± (1.5 % R +0.1)
4.24 78 (Cab)
Damp heat
(steady state)
56days; 40°C;90% to95 %RH;
loaded with 0.01P
70
(Steps: 0V to100V)
R
ins min.
: 1000M
R
max.
:± (3 %R +0.1)
4.25.1
Endurance
(at70 °C)
1000h; loaded with P
70
or U
max.
;
1.5h ON and 0.5h OFF
R
max.
:± (5 %R +0.1)
4.8
Temperature
coefficient
Between - 55 °C and + 155 °C ± 250 ppm/K
4.6.1.1 Insulation resistance
Maximum voltage (DC) after 1min;
metal block method
R
ins min.
: 10
4
M
TEST PROCEDURES AND REQUIREMENTS
IEC
60115-1
CLAUSE
IEC
60068-2-
TEST
METHOD
TEST PROCEDURE REQUIREMENTS