For T58M0476M6R3C0500 and T58M0476M6R3C0300 surge voltage testing temperature is 60 °C
STANDARD PACKAGING QUANTITY
CASE CODE UNITS PER 7" REEL
MM / M0 4000
W0 3000
W9 4000
A0 3000
AA 2000
B0 3000
BB 2000
PERFORMANCE CHARACTERISTICS
ITEM CONDITION POST TEST PERFORMANCE
Life test at +105 °C 2000 h application of rated voltage at 105 °C,
MIL-STD-202 method 108
Capacitance change Within ± 20 % of initial value
Dissipation factor Within initial limits
Leakage current Shall not exceed 300 % of initial limit
Humidity tests At 60 °C / 90 % RH 500 h, no voltage applied Capacitance change -20 % to +40 % of initial value
Dissipation factor Within initial limit
Leakage current Shall not exceed 300 % of initial limit
Stability at low and
high temperatures
-55 °C Capacitance change Within -20 % to 0 % of initial value
Dissipation factor Shall not exceed 150 % of initial limit
Leakage current n/a
25 °C Capacitance change Within ± 20 % of initial value
Dissipation factor Within initial limit
Leakage current Within initial limit
105 °C Capacitance change
Within -50 % to +30 % of initial value
Dissipation factor Within initial limits
Leakage current Shall not exceed 1000 % of initial limits
Surge voltage
(1)
85 °C, 1000 successive test cycles at 1.3 of
rated voltage in series with a 1 k resistor at
the rate of 30 s ON, 30 s OFF
Capacitance change Within ± 20 % of initial value
Dissipation factor Within initial limit
Leakage current Shall not exceed 300 % of initial limit
Shock
(specified pulse)
MIL-STD-202, method 213, condition I,
100 g peak
Capacitance change Within ± 20 % of initial value
Dissipation factor Within initial limit
Leakage current Shall not exceed 300 % of initial limit
Vibration MIL-STD-202, method 204, condition D,
10 Hz to 2000 Hz 20 g peak
There shall be no mechanical or visual damage to capacitors
post-conditioning.
Shear test Apply a pressure load of 5 N for 10 s ± 1 s
horizontally to the center of capacitor side body
Capacitance change Within ± 20 % of initial value
Dissipation factor Within initial limit
Leakage current Shall not exceed 300 % of initial limit
PRODUCT INFORMATION