Datasheet

Polymer Guide
www.vishay.com
Vishay
Revision: 09-Apr-2019
8
Document Number: 40076
For technical questions, contact: polytech@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
PACKING AND STORAGE
Polymer capacitors meet moisture sensitivity level rating (MSL) of 3 or 4 as specified in IPC/JEDEC
®
J-STD-020 and are dry
packaged in moisture barrier bags (MBB) per J-STD-033. MSL for each particular family is defined in the datasheet - either in
“Features” section or “Standard Ratings” table. Level 3 specifies a floor life (out of bag) of 168 hours and level 4 specifies a floor
life of 72 hours at 30 °C maximum and 60 % relative humidity (RH). Unused capacitors should be re-sealed in the MBB with
fresh desiccant. A moisture strip (humidity indicator card) is included in the bag to assure dryness. To remove excess moisture,
capacitors can be dried at 40 °C (standard “dry box” conditions).
For detailed recommendations please refer to J-STD-033.
Notes
T52, T55, and T58 capacitors are process sensitive.
PSL classification to JEDEC J-STD-075: R4G
T54 and T59 capacitors with 100 % tin termination are process sensitive.
PSL classification to JEDEC J-STD-075: R6G
RECOMMENDED REFLOW PROFILES
Vishay recommends no more than 3 cycles of reflow in accordance with J-STD-020.
PROFILE FEATURE SnPb EUTECTIC ASSEMBLY LEAD (Pb)-FREE ASSEMBLY
PREHEAT AND SOAK
Temperature min. (T
Smin.
) 100 °C 150 °C
Temperature max. (T
Smax.
) 150 °C 200 °C
Time (t
S
) from (T
Smin.
to T
Smax.
) 60 s to 120 s 60 s to 120 s
RAMP UP
Ramp-up rate (T
L
to T
p
) 3 °C/s maximum
Liquidus temperature (T
L
) 183 °C 217 °C
Time (t
L
) maintained above T
L
60 s to 150 s
Peak package body temperature (T
p
) max. Depends on type and case - see table below
Time (t
p
) within 5 °C of the peak max. temperature 20 s 5 s
RAMP DOWN
Ramp-down rate (T
p
to T
L
) 6 °C/s maximum
Time from 25 °C to peak temperature 6 min maximum 8 min maximum
PEAK PACKAGE BODY TEMPERATURE (T
p
) MAXIMUM
TYPE CASE CODE
PEAK PACKAGE BODY TEMPERATURE (T
P
) MAX.
SnPb EUTECTIC ASSEMBLY LEAD (Pb)-FREE ASSEMBLY
T55 J, P, A, T, B, Z, V, D
n/a
260 °C
T52 E5, M1 260 °C
T58 MM, M0, W9, W0, A0, AA, B0, BB 260 °C
T59 EE 220 °C 250 °C
T54 EE 220 °C 250 °C
Time
Temperature
t
S
Time 25 °C to peak
t
p
T
P
T
L
T
Smin.
25
t
L
T
Smax.
Preheat area
Max. ramp up rate = 3 °C/s
Max. ramp down rate = 6 °C/s