Note
Test conditions per JIS C5101-1
PERFORMANCE CHARACTERISTICS
ITEM CONDITION POST TEST PERFORMANCE
Temperature
characteristics
Measure the specified
characteristics in each stage
Specified
initial
value
-55 °C +85 °C +125 °C
Capacitance change - -12 % to 0 % 0 % to 10 % 0 % to 12 %
Dissipation factor (%),
maximum
45 4 5
68 6 6
812 10 12
10 14 12 14
12 16 14 16
18 34 20 22
20 38 22 24
30 60 30 40
Leakage current
Refer to
Standard
Ratings
table
-
1000 %
specified
initial value
or less
1250 %
specified
initial value
or less
Solder heat
resistance
Solder Dip
260 °C ± 5 °C, 10 s ± 1 s
Reflow
260 °C, 10 s ± 1 s
Capacitance change Within ± 5 % of initial value
Dissipation factor Initial specified value or less
Leakage current Initial specified value or less
Moisture
resistance
no load
Leave at 40 °C and 90 % to 95 % RH
for 500 h
Capacitance change Within ± 10 % of initial value
Dissipation factor Initial specified value or less
Leakage current Initial specified value or less
High
temperature
load
85 °C. The rated voltage is applied
for 2000 h
Capacitance change Within ± 10 % of initial value
Dissipation factor Initial specified value or less
Leakage current Shall not exceed 125 % of initial specified value
Thermal shock
Leave at -55 °C, normal temperature,
125 °C, and normal temperature for
30 min., 3 min, 30 min, and 3 min.
Repeat this operation 5 times running.
Capacitance change Within ± 5 % of initial value
Dissipation factor Initial specified value or less
Leakage current Initial specified value or less
Moisture
resistance
load
Leave at 40 °C and 90 % to 95 % RH.
The rated voltage applied for 500 h
Capacitance change Within ± 10 % of initial value
Dissipation factor Shall not exceed 150 % of initial specified value
Leakage current Shall not exceed 200 % of initial specified value
Failure rate
85 °C. The rated voltage is applied
through a protective resistor of 1 /V.
1 % / 1000 h