Datasheet

Document Number: 83748 For technical questions, contact: optocoupleranswers@vishay.com
www.vishay.com
Rev. 1.9, 20-Oct-10 3
VO3062, VO3063
Phototriac, Zero Crossing, 1.5 kV/μs dV/dt,
600 V
Vishay Semiconductors
Note
Typical values are characteristics of the device and are the result of engineering evaluations. Typical values are for information only and are
not part of the testing requirements.
Note
As per IEC60747-5-5, § 7.4.3.8.1, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with
the safety ratings shall be ensured by means of prodective circuits.
COUPLER
LED trigger current,
current required to latch output
VO3063 I
FT
5mA
VO3062 I
FT
10 mA
Peak on-state voltage,
either direction
I
TM
= 100 mA Peak,
I
F
= Rated I
FT
V
TM
1.7 3 V
Holding current, either direction I
H
200 μA
Inhibit voltage (MT1-MT2 voltage
above which device will not trigger)
V
INH
12 22 V
Leakage in inhibited state
I
F
= 10 mA maximum,
at rated V
DRM
, off state
V
DRM2
250 1000 μA
SAFETY AND INSULATION RATINGS
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Climatic classification IEC68 part 1 40/85/21
Pollution degree DIN VDE 0109 2
Comparative tracking index per DIN IEC112/VDE 0303 part 1,
group IIIa per DIN VDE 6110 175 399
CTI 175
Highest allowable overvoltage
Transient
overvoltage
V
IOTM
8000 V
peak
Maximum working insulation voltage
Recurring peak
voltage
V
IORM
890 V
peak
Insulation resistance at 25 °C V
IO
= 500 V R
IS
10
12
Ω
Insulation resistance at T
S
V
IO
= 500 V R
IS
10
9
Ω
Insulation resistance at 100 °C V
IO
= 500 V R
IS
10
11
Ω
Partial discharge test voltage
Method a,
V
pd
= V
IORM
x 1.875
V
pd
1325 V
peak
Safety limiting values -
maximum values allowed in the
event of a failure
Safety power rating P
SO
400 mW
Safety current rating I
SI
150 mA
Safety temperature
rating
T
SI
165 °C
Minimum external air gap (clearance)
Measured from input
terminals to output
terminals, shortest
distance through air
7mm
Minimum external tracking (creepage)
Measured from input
terminals to output
terminals, shortest
distance path along
body
7mm
ELECTRICAL CHARACTERISTCS (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT