Datasheet

VOL617A
www.vishay.com
Vishay Semiconductors
Rev. 2.0, 13-Oct-15
3
Document Number: 82424
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 2 - Test Circuit Fig. 3 - Test Circuit and Waveforms
Note
According to DIN EN 60747-5-5 (VDE 0884-5), § 7.4.3.8.2, (see figure 4). This optocoupler is suitable for safe electrical isolation only within
the safety ratings. Compliance with the safety ratings shall be ensured by means of suitable protective circuits.
CURRENT TRANSFER RATIO (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT
I
C
/I
F
I
F
= 5 mA, V
CE
= 5 V
VOL617A CTR 50 - 600 %
VOL617A-1 CTR 40 - 80 %
VOL617A-2 CTR 63 - 125 %
VOL617A-3 CTR 100 - 200 %
VOL617A-4 CTR 160 - 320 %
VOL617A-7 CTR 80 - 160 %
VOL617A-8 CTR 130 - 260 %
SWITCHING CHARACTERISTICS (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Turn on time V
CC
= 5 V, I
C
= 2 mA, R
L
= 100 Ω t
on
-6-μs
Rise time V
CC
= 5 V, I
C
= 2 mA, R
L
= 100 Ω t
r
-3.5- μs
Turn off time V
CC
= 5 V, I
C
= 2 mA, R
L
= 100 Ω t
off
-5.5- μs
Fall time V
CC
= 5 V, I
C
= 2 mA, R
L
= 100 Ω t
f
-5-μs
isfh618a_10
Input
V
OUT
V
CC
= 5 V
R
L
isfh618a_12
10 %
90 %
Input pulse
Output pulse
t
r
t
on
t
f
t
off
SAFETY AND INSULATION RATINGS
PARAMETER TEST CONDITION SYMBOL VALUE UNIT
Partial discharge test voltage - routine test 100 %, t
test
= 1 s V
pd
2kV
Partial discharge test voltage -
lot test (sample test)
t
Tr
= 60 s, t
test
= 10 s,
(see figure 4)
V
IOTM
8kV
V
pd
1.68 kV
Maximum withstanding isolation voltage t = 1 min V
ISO
5000 V
RMS
Insulation voltage V
IORM
1050 V
peak
Insulation resistance
V
IO
= 500 V
DC
, T
amb
= 25 °C R
IO
10
12
Ω
V
IO
= 500 V
DC
, T
amb
= 100 °C R
IO
10
11
Ω
V
IO
= 500 V
DC
, T
amb
= 150 °C
(construction test only)
R
IO
10
9
Ω
Safety rating - maximum input current I
si
130 mA
Safety rating - maximum power dissipation P
SO
265 mW
Rated impulse voltage V
IOTM
8kV
Safety rating - maximum ambient temperature T
si
150 °C
Comparative tracking index CTI 275
Clearance distance 8mm
Creepage distance 8mm
Insulation distance (internal) DTI 0.4 mm