Datasheet

Document Number: 94163 For technical questions, contact: diodestech@vishay.com
www.vishay.com
Revision: 12-Mar-10 1
Schottky Rectifier, 2 x 10 A
VS-20CTQ...SPbF, VS-20CTQ...-1PbF Series
Vishay High Power Products
FEATURES
175 °C T
J
operation
Center tap TO-220 package
Low forward voltage drop
High frequency operation
High purity, high temperature epoxy
encapsulation for enhanced mechanical
strength and moisture resistance
Guard ring for enhanced ruggedness and long
term reliability
Meets MSL level 1, per J-STD-020, LF maximum peak of
260 °C
Halogen-free according to IEC 61249-2-21 definition
Compliant to RoHS directive 2002/95/EC
AEC-Q101 qualified
DESCRIPTION
The VS-20CTQ... center tap Schottky rectifier series has
been optimized for low reverse leakage at high temperature.
The proprietary barrier technology allows for reliable
operation up to 175 °C junction temperature. Typical
applications are in switching power supplies, converters,
freewheeling diodes, and reverse battery protection.
PRODUCT SUMMARY
I
F(AV)
2 x 10 A
V
R
35 V to 45 V
VS-20CTQ...SPbF
D
2
PAK
TO-262
VS-20CTQ...-1PbF
Base
common
cathode
A
node Anode
Common
cathode
1
3
2
2
Base
common
cathode
Anode Anode
Common
cathode
1
3
2
2
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL CHARACTERISTICS VALUES UNITS
I
F(AV)
Rectangular waveform 20 A
V
RRM
Range 35 to 45 V
I
FSM
t
p
= 5 μs sine 1060 A
V
F
10 Apk, T
J
= 125 °C (per leg) 0.57 V
T
J
Range - 55 to 175 °C
VOLTAGE RATINGS
PARAMETER SYMBOL
VS-20CTQ035SPbF
VS-20CTQ035-1PbF
VS-20CTQ040SPbF
VS-20CTQ040-1PbF
VS-20CTQ045SPbF
VS-20CTQ045-1PbF
UNITS
Maximum DC reverse voltage V
R
35 40 45 V
Maximum working peak reverse voltage V
RWM
ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum average forward current
See fig. 5
I
F(AV)
50 % duty cycle at T
C
= 145 °C, rectangular waveform 20
A
Maximum peak one cycle non-repetitive
surge current per leg
See fig. 7
I
FSM
5 μs sine or 3 μs rect. pulse
Following any rated load
condition and with rated
V
RRM
applied
1060
10 ms sine or 6 ms rect. pulse 265
Non-repetitive avalanche energy per leg E
AS
T
J
= 25 °C, I
AS
= 2.0 A, L = 6.5 mH 13 mJ
Repetitive avalanche current per leg I
AR
Current decaying linearly to zero in 1 μs
Frequency limited by T
J
maximum V
A
= 1.5 x V
R
typical
2.0 A