Service manual

20
CHAPTER 2: ENGINEERING MODE
2.6 Engineering Mode Overview – Touch Console – Continued
2.6.2 Touch Console – Default Tab – Continued
Engineer
Mode - Default
Function and Default Descriptions Modified
Time Maximum Workout Time
Default: 99 minutes
This option enables you to set the maximum
workout duration limits
Maximum: 99 Minutes
Minimum: 5 Minutes
Default Workout Time
Default: 20 minutes
This option enables you to set user default workout
time
Maximum: 99 Minutes
Minimum: 5 Minutes
Pause Time
Default: 5 minutes
This option enables you to set workout pause time,
the console will reset when this time expires
Maximum: 99 Minutes
Minimum: 5 Minutes
Warm Up Time
Default: 2 minutes
This option enables you to set user’s warm up time Maximum: 99 Minutes
Minimum: 5 Minutes
Cool Down Time
Default: 5 minutes
This option enables you to set users Cool Down
Time after a workout
Maximum: 99 Minutes
Minimum: 5 Minutes
Age Default Age
Default: 30
This option enables you to set the user’s default age
if not selected during setup
Maximum: 99
Minimum: 13
Weight Default Weight
Default:150LBS
This option enables you to set user’s default
weight if not selected during setup
Maximum: 375LBS
Minimum: 55LBS
Gender Default Gender
Default: Male
This option enables you to set user’s gender if not
selected during setup
Male/Female
Volume Default Volume
Default: 20
This option enables you to set speaker or earphone
volume
Maximum: 20
Minimum: 0
Heart Rate Default Target Heart Rate
Default: 85%
This option enables you to set target heart rate for
some heart rate programs
Maximum:100%
Minimum: 0
Brightness Brightness
Default: 75%
This option enables you to set the LCD panel
brightness level
Maximum:100%
Minimum: 0
Virtual Active
Message
VA Message
Default: on
This option enables you to set the VA, user can
choose the VA message displayed on the screen or
not
On/off
Virtual Active
Music
VA Music
Default: on
This option enables you to set the VA, user can
choose the VA music played or not
On/off
Use the same operation as Max Workout Time to adjust the other Default information.
Press "Restore" to restore to the factory settings.