TECHCONNECT CONTROL3 OWNERS MANUAL www.visionaudiovisual.
DECLARATION OF CONFORMITY Where applicable Vision products are certified and comply with all known local regulations to a ‘CB Certification’ standard. Vision commits to ensure all products are fully compliant with all applicable certification standards for sale in the EU and other participating countries. The product described in this owner manual is in compliance with RoHS (EU directive 2002/95/EC), and WEEE (EU directive 2002/96/EC) standards.
USE ONLY DOMESTIC AC OUTLETS Connecting the unit to an outlet supplying a higher voltage may create a fire hazard. HANDLE THE POWER CORD WITH CARE Do not disconnect the plug from the AC outlet by pulling the cord; always pull the plug itself. Pulling the cord may damage it. If you do not intend to use your unit for any considerable length of time, unplug the unit. Do not place furniture or other heavy objects on the cord, and try to avoid dropping heavy objects on it. Do not tie a knot in the power cord.
FRONT AND REAR PANELS 3 2 6 4 1 7 8 9 5 1. 2. 3. 4. 5. 10 Learn Confirmation LED (green) Learn Mode LED (red) IR Receiver Internal IR Blaster / Emitter Function Buttons 6. RS-232 7. PWR in (12V 0.5A) 8. 12V Trigger out 9. RS-485 10.
CONTROL OPTIONS IR Techconnect Control learns and replicates codes sent from a device’s infrared remote control. An IR emitter integrated into the front panel is adequate for small rooms. For larger rooms three external wired IR emitters are included – one with a 10m cable, and two without cables. Techconnect Minijack cables are suitable to extend these. NOTE: There is no theoretical cable length limit on IR cables. NOTE: Remote controls which come with projection screens are often RF – not IR.
INSTALLATION 1. FIT LABELS Use flat-head screwdriver to unclip clear button covers, then apply labels as shown: 2. SELECT POWER SOURCE The control module is set to be powered by mains power by default. If you choose to power with 2 x AAA batteries (not included) move switch inside the battery compartment to BATT. NOTE 1: If powered by batteries buttons will only light when pressed. NOTE 2: If powered by mains ensure batteries are not left in device. 3.
SIMPLE MODE PROGRAMMING Appropriate for controlling one IR device only, e.g. projector. 1. PUT DEVICE INTO LEARN MODE Press and hold buttons 3 and 4 (middle buttons). The learn LED on the front panel will turn red and stay on. 2. PRESS BUTTON TO ASSIGN CODE TO Press function button on the front panel which the incoming code will be assigned to. One code can be assigned to each button. 3. TEACH CODE Point remote control at the front panel of Control module.
ADVANCED MODE PROGRAMMING NOTE: Device must use mains-power for these advanced functions. Use • • • • • when you need to Program multiple codes to each button Use RS-232 or 12v trigger Add an extension keypad Program scheduled actions Duplicate to multiple devices 1. LOAD SOFTWARE ONTO PC Download from Vision’s website: www.visionaudiovisual.com/techconnect/tc2-ctl3 2. CONNECT CONTROL MODULE VIA USB In the battery compartment there is a standard USB-B mini connector.
NOTE: When you press ‘learn’ in software wait until the red LED appears on the module, then point original remote at front of module and press and hold button. 6. SCHEDULE LAST If using the scheduling function, do this once all of the codes have been learnt. IMPORTANT: The software contains a pre-set library of RS-232 codes. When you add new codes and sync and software, those new codes become available to all users when they sync and can be edited.
Module learns code but doesn’t control the projector • • • • Re-program the buttons.
SPECIFICATIONS PRODUCT DIMENSIONS: 71 x 42 x 31mm (length x width x height) PRODUCT WEIGHT: 63 grams CONSTRUCTION MATERIAL: Plastic COLOUR: White POWER SUPPLY: 100-240v AC 50/60Hz External Power Supply – integrated transformer/plug type. DC Output 12V 0.5A, DC Cable 3m, Transformer size: 62 x 42 x 22 mm. Interchangeable prongs including UK, EU, AU, US. Note: a normal figure-8 cable can be plugged into the transformer if preferred.
time and without notice. Such changes will be incorporated into new editions of the User Manual.