User`s manual
AW00049313000 Acquisition Control
Basler runner 101
Fig. 36: Use Case Diagram - Continuous Frame Mode with Acquisition Start and Line Start Triggering Set to Off
and Frame Start Triggering Set to On
Time
Acquisition
start
command
Acquisition
stop
command
Acquisition start
trigger signal
Frame start
trigger signal
Line start
trigger signal
Settings:
Acquisition Mode = Continuous Frame
Acquisition Start Trigger Mode = Off
Frame Start Trigger Mode = On
Frame Start Trigger Source = Line 2
Frame Start Trigger Activation = Rising Edge
Lines Per Frame (Height) = 3
Line Start Trigger Mode = Off
= trigger signal internally generated by the camera
= trigger signal applied by the user
= camera is waiting for an acquisition start trigger signal
= camera is waiting for a frame start trigger signal
= camera is waiting for a line start trigger signal
= line exposure and readout
= frame transmitted