User`s manual
AW00049313000 Acquisition Control
Basler runner 105
Fig. 38: Use Case Diagram - Continuous Frame Mode with Acquisition Start Triggering Set to Off, Frame Start and
Line Start Triggering Set to On, and Partial Closing Frame set to False
Time
Acquisition
start
command
Acquisition
stop
command
Acquisition start
trigger signal
Frame start
trigger signal
Line start
trigger signal
Settings:
Acquisition Mode = Continuous Frame
Acquisition Start Trigger Mode = Off
Frame Start Trigger Mode = On
Frame Start Trigger Source = Line 2
Frame Start Trigger Activation = Level High
Partial Closing Frame = False
Lines Per Frame (Height) = 3
Line Start Trigger Mode = On
Line Start Trigger Source = Line 3
Line Start Trigger Activation = Rising Edge
= trigger signal internally generated by the camera
= trigger signal applied by the user
= camera is waiting for a frame start trigger signal
= camera is waiting for a line start trigger signal
= line exposure and readout
= line start trigger signal is ignored because the camera is waiting for a frame start trigger signal
= frame transmitted
= camera is waiting for an acquisition start trigger signal