User`s manual

AW00049313000 Acquisition Control
Basler runner 109
Fig. 40: Use Case Diagram - Continuous Frame Mode with Acquisition Start and Frame Start Triggering Set to Off
and Line Start Triggering Set to On
Time
Acquisition
start
command
Acquisition
stop
command
Acquisition start
trigger signal
Frame start
trigger signal
Line start
trigger signal
Settings:
Acquisition Mode = Continuous Frame
Acquisition Start Trigger Mode = Off
Frame Start Trigger Mode = Off
Lines Per Frame (Height) = 3
Line Start Trigger Mode = On
Line Start Trigger Source = Line 3
Line Start Trigger Activation = Rising Edge
= trigger signal internally generated by the camera
= trigger signal applied by the user
= camera is waiting for an acquisition start trigger signal
= camera is waiting for a frame start trigger signal
= camera is waiting for a line start trigger signal
= line exposure and readout
= complete frame transmitted
= partial frame transmitted