User`s manual
AW00049313000 Acquisition Control
Basler runner 111
Fig. 41: Use Case Diagram - Continuous Frame Mode with Acquisition Start Triggering Set to On and Frame Start
and Line Start Triggering Set to Off
Time
Acquisition
start
command
Acquisition
stop
command
Acquisition start
trigger signal
Frame start
trigger signal
Line start
trigger signal
Settings:
Acquisition Mode = Continuous Frame
Acquisition Start Trigger Mode = On
Acquisition Start Trigger Source = 1
Acquisition Start Trigger Activation = Rising Edge
Acquisition Frame Count = 2
Frame Start Trigger Mode = Off
Lines Per Frame (Height) = 3
Line Start Trigger Mode = Off
= trigger signal internally generated by the camera
= trigger signal applied by the user
= camera is waiting for an acquisition start trigger signal
= camera is waiting for a frame start trigger signal
= camera is waiting for a line start trigger signal
= line exposure and readout
= frame transmitted