User`s manual
Standard Features AW00049313000
192 Basler runner
You can set the LUT Selector, the LUT Index parameter and the LUT Value parameter from within
your application software by using the pylon API. The following code snippet illustrates using the
API to set the selector and the parameter values:
// Select the lookup table
Camera.LUTSelector.SetValue( LUTSelector_Luminance );
// Write a lookup table to the device.
// The following lookup table causes an inversion of the sensor values
// ( bright -> dark, dark -> bright )
for ( int i = 0; i < 4096; i += 8 )
{
Camera.LUTIndex.SetValue( i );
Camera.LUTValue.SetValue( 4095 - i );
}
// Enable the lookup table
Camera.LUTEnable.SetValue( true );
For detailed information about using the pylon API, refer to the Basler pylon Programmer’s Guide
and API Reference.
You can also use the Basler pylon Viewer application to easily set the parameters.