User's Manual

2015-07-31
V029627_02_WOFS_Installation_Guide.docx Page 5 of 20
Connecting Power
The Receiver is powered by +12 VDC supplied by the facility where the Receiver is installed.
1. Connect power to the terminals by removing the 4 recessed, Phillips-head screws and
open the case to access the terminal blocks.
2. Turn off the source of the facility’s +12VDC.
3. Connect +12 VDC wire and ground wire to Receiver’s DC Power terminals. Run the
wires across the Strain Relief Zip ties, and through the hole next to the SMA antenna
connector (see yellow-highlighted boxes in Figure 4).
Figure 4 - Receiver PC board and terminal blocks
4. Connect the +12VDC wire and ground wire to the facility’s power source, following
NEC guidelines.
NOTE: Do NOT turn on the power source until all of the wiring process is
complete, as instructed later in this manual.