6. Place the calibration page, with the black bar face up, into the scanner.
7. The scanner pulls in the calibration page and feeds it slowly through the paper path.
8. When calibration is complete the scanner will clear the calibration page out of the scanner. Remove the
calibration page when the utility prompts you to. Do not forcefully pull the page out of the scanner, the
scanner will release the page when it has fully exited out of the scanner.
CALIBRATION ERROR
If there is an error during calibration or if the scanner should disconnect during calibration. The error will display
on-screen. If you see a message that calibration failed, please run the calibration utility again.
N
OTE: if you attempted to calibrate the scanner with any page other than the calibration page provided with your
scanner, the calibration routine will fail. You will need to power cycle the scanner, through unplug then re-plug of
the USB cable, and then restart the calibration.