Quick Start Guide

DE5803Q 1
DL-125C, DL-125CA
Programmable 2-channel Speech Dialer
Quick Start Guide
1. PROGRAMMING REGULAR PHONE NUMBERS
The dialer can call up to 4 regular phone numbers per
zone. To program the numbers to be called when zone 1
(Z1) is in alarm:
Press
- this selects location 1.
After the dial LED flashes twice, enter phone number to
dial.
Finish by pressing
.
Example:
- this would dial phone
number 555-1212 and deliver the message programmed for
zone 1.
Program the remaining phone numbers (2, 3 and 4) as above.
For example:
Press
- this selects location 2.
After the dial LED flashes twice, enter phone number to
dial.
Finish by pressing
.
Program numbers for zone 2 (Z2) in the same manner,
except that the location numbers will be 5, 6, 7, & 8. Start with
pressing
- this selects location 5.
2. PROGRAMMING NUMERIC PAGERS
Pagers require two phone number locations. Therefore,
each DL-125C / DL-125CA zone can call a maximum of two
pagers. Proceed as follows to program pagers into zone 1:
Press
- this selects location 1.
After the dial LED flashes twice, enter the phone number of
the numeric pager.
Press
- this links the current location with the next for
pager function.
Press
.
Press
- this selects location 2.
After the dial led flashes twice, press
- this links this
location to the previous location for pager function.
Press
to provide a 10-second delay allowing the
paging company to pick up (you can enter any two digit
value, but 10 seconds works in most cases).
Enter the number you wish to appear on the pager’s display
and finish by pressing
.
Example:
and then:
- this would deliver
the message “9999” to a pager at phone No. 555-2525.
If you wish to program another pager in zone 1, follow these
same steps, but use locations 3 and 4. To program pagers
into zone 2, use locations 5 & 6 and/or locations 7 & 8.
3. RECORDING VOICE MESSAGES
The DL-125C / DL-125CA contains three locations for voice
messages. The total recording time can not exceed 19 seconds.
Location / common message (up to 14.5 sec.) - name and
address that is common to AL-1 and AL-2 messages.
Message AL-1 (up to 2.5 sec.) is the alarm type message for
zone 1 (burglar alarm activation, for example).
Message AL-2 (up to 2 sec.) is the alarm type message for
zone 2 (low temperature detection, for example).
You must record at least
the common message and one of
the alarm messages (AL-1 or AL-2). You cannot record only a
common message. Recording should be done in the following
order:
To record AL-1 & AL-2 (location message):
Press
Press and hold both
and
buttons at the same time
while reading the message aloud - red LED will be on.
Release
and
and press
- red LED will turn off.
To record AL-1 message:
Press
Press and hold
while reading the message aloud - red
LED will be on.
Release
and press
- red LED will turn off.
To record AL-2 message:
Press
Press and hold while reading the message aloud - red
LED will be on.
Release
and press
- red LED will turn off.
For more advanced applications, refer to the DL-125C installation instructions, or contact the technical support.
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): ):
65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT. 06002-1376. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 7300800 FAX: (0870) 7300801
INTERNET: www.visonic.com
©VISONIC LTD. 2008 DL-125C, DL-125CA DE5803Q (REV. 1, 10/08)

Summary of content (1 pages)