Figure 6: Battery removal and insertion
5. Press down on the battery until it fits into place.
6. Close the device cover. See figure 5 C.
Note: After restoring a low battery, the system may take up to 5 minutes to clear the
trouble.
Directional magnet distances for event triggers
The following figure and table display the directional magnet distances that trigger open or close
events.
Figure 7: Range coverage directions
Table 2: Directional magnet distances for event triggers
Non-metallic surface Supports Metallic surface
Opening Closing Direction Opening Closing
27 mm (1.06 in.) 23 mm (0.91 in.) X 12 mm (0.47 in.) 10 mm (0.39 in.)
16 mm (0.63 in.) 14 mm (0.55 in.) Y 15 mm (0.59 in.) 12 mm (0.47 in.)
27 mm (1.06 in.) 22 mm (0.87 in.) Z 26 mm (1.02 in.) 21 mm (0.83 in.)