User's Manual

D-306082 MP-840 PIR ZB 1
MP-840
ZigBee Home Automation 1.2
Wireless Digital Pet Immune PIR Detector
Installation Instructions
1. INTRODUCTION
The MP-840 (pet immune) is a microprocessor-controlled wireless digital PIR detector supported by H.A 1.2
panels using ZigBee Home Automation.
The detector’s features are as follows:
Fresnel and cylindrical lenses with uniform detection sensitivity throughout its operating range, up to 12
meters (39 ft).
Target Specific Imaging™ (TSI) technology is used for distinction between humans and pets weighing
up to 38 kg (85lb).
The advanced True Motion Recognition™ algorithm (patented) allows distinguishing between the true
motion of an intruder and any other disturbances which may cause false alarms.
No vertical adjustment is needed.
An on-board motion event jumper determines whether 1 or 2 consecutive motion events trigger an
alarm.
After detection, the detector disarms itself to save battery power. It rearms (reverts to the ready state) if
there is no subsequent detection throughout the following 2-minute period.
Very low current consumption.
Microprocessor-controlled temperature compensation.
White light protection.
Front and back tamper protection.
Elegantly styled, sturdy case.
The device support on temperature’s report according to HA1.2’s panel.
For UL installations: The detector is for use with UL listed control unit only. Pet immunity has not been
evaluated by UL.
Figure 1: MP-840
2. SPECIFICATIONS
Detector Type
Dual element low
-
OPTICAL
Lens Data
Max. Coverage
Pet Immunity (pet version)
27 Fresnel “far” lenses (54 sensitivity “beams”)
18 cylinder “mid” curtain lenses (36 sensitivity “curtains”)
10 cylinder “close” curtain lenses (20 sensitivity “creep curtains”)
12 x 12 m, (39 x 39 ft) / 90°
Up to 38 kg (85 lb)
ELECTRICAL
Internal Battery
3V Lithium battery, type CR
-
123A. For UL installations, use
Panasonic
and GP only
Nominal Battery Capacity
1450 mAh
Battery Life (with LED on)
Battery Power Test
FUNCTIONAL
Typically over 5 years
Note: Inability to connect with wireless network, or wireless link quality no higher than 20% may
significantly reduce the expected battery life.
Performed immediately upon battery insertion and periodically after every several hours
True Motion Event
Verification
2 position selector - 1 (OFF) or 2 (ON) motion events
Alarm Period
2 seconds
LED Switch
LED Enable (red LED lights for 2 sec. upon Alarm detection)
LED Disable: No indication. (LED is always enabled during Walk-Test mode)
Rearm Timer
Rearms the detector 2 minutes after the last alarm. Timer disabled in the walk test mode

Summary of content (8 pages)