User guide
  Chapter 6: Data Details Tables 
DE5450S Remote Programmer Guide Rev. 9  35 
1.  Enroll the keyfob transmitter to the control panel as detailed in the 
PowerMax Installer Guide. 
  Note: Remember the keyfob number to which you enrolled the keyfob. 
2.  Connect and log in via serial connection to the panel as detailed in 
chapter 7: “Connecting to the Control Panel”. 
3.  Upload the keyfob data from the panel. 
4.  In the Keyfob Enrollment table, enter the keyfob ID, the sync. counter and 
the sync. counter backup numbers displayed on the screen next to the 
keyfob number you enrolled the keyfob to. 
5.  Log out and disconnect from the control panel. 
6.  Connect and log in to your customer’s PowerMax control panel. 
7.  Click the Options icon in the tool bar or select Options in the View 
menu. 
8.  Select the Data tab. 
9.  Check the Send updated data immediately checkbox. 
10.  Enter the keyfob ID, the sync. counter and the sync. counter backup 
numbers to the relevant keyfob in the Keyfob Enrollment table.  
  Every cell you update will be automatically downloaded to the customer’s 
control panel. (Be sure not to change other parameters.) 
11.  Logout and disconnect. 
Now all you have to do is to send the keyfob transmitter to your customer! 
To Delete a Keyfob 
In the ID column, change the ID to 00000000, and then download to the 
control panel as detailed in chapter 7: Connecting to the Control Panel. 
6.14 Keyfob Enrollment (PowerG) 
Keyfobs, such as KF-234 PG2 and KF-235 PG2 are two-way 4-button keyfobs 
used for arming/disarming of the system and for viewing system status (KF-235 
PG2). 
The table displays information about all installed keyfobs and their enrollment 
status. The data also includes the keyfob number and RF ID, received signal 
strength indication (24-hour and current RSSI) quality of the device (Strong; Good; 
Poor; or Not OK), device configuration and walk-test. 
The Remote Programmer enables pre-enrolling and deleting keyfobs. 