User guide
  Chapter 6: Data Details Tables 
DE5450S Remote Programmer Guide Rev. 9  39 
To Delete a Repeater 
1.  In the Repeater Enrollment table, click the Action button   of the 
repeater to be deleted. 
2.  From the dialog box, select the Delete Device radio button. 
3.  Click the Send to Panel button. 
4.  A new dialog box opens asking Are you sure?; click Yes. 
5.  Click Close. 
The repeater is now deleted from the system. 
6.16 Keypad Enrollment 
An MCM-140 (one-way) keypad is a multi-button wireless keypad unit. The number 
of supported keypads can vary according to the installed control panel. 
In order that the control panel and the Remote Programmer will recognize the 
Keypads, each one must be enrolled in the system, and assigned a keypad 
number in the panel. Keypad initiated events are subsequently identified and 
registered with reference to these numbers. 
In the PowerCode version, this table displays the keypad ordinal number, an 
indication whether the keypad has been enrolled, the keypad ID, the keypad sync. 
counter and the keypad sync. backup. 
In the PowerG version, this table displays information about all installed keypads 
and their enrollment status. For PowerG installations, the data also includes the 
keyfob number and RF ID, received signal strength indication (24-hour and current 
RSSI) quality of the device (Strong; Good; Poor; or Not OK), device configuration 
and walk-test. 
The Remote Programmer enables enrolling and deleting keypads. 
To Enroll a Keypad to the Control Panel 
In order to perform this procedure, collect together: 
A PowerMax/PowerMaster control panel, which will be used to pass the keypad 
identifying information from the keypad through to the PC and from there to the 
customer’s control panel. 