User guide
  Chapter 6: Data Details Tables 
DE5450S Remote Programmer Guide Rev. 9  45 
To Delete a Pendant 
1.  In the Pendant Enrollment table, click the Action button   of the 
pendant to be deleted. 
2.  From the dialog box, select the Delete Device radio button. 
3.  Click the Send to Panel button. 
4.  A new dialog box opens asking Are you sure?; click Yes. 
5.  Click Close. 
The pendant is now deleted from the system. 
6.19 Zone Definitions 
Zone Definitions allows you to attribute one of the zone types to any one of the 
wireless zones offered by the PowerMax/PowerMaster. 
In the PowerCode version, you can assign a name to each zone and determine 
whether the zone will operate as a chime zone while the system is in the disarmed 
state. 
After uploading data from the PowerMaster
∗
∗∗
∗
 you can view the RF ID numbers of all 
enrolled devices. The received signal strength indication (RSSI) of the device can 
also be viewed after pressing on the UL Table icon and then pressing "OK". 
In the PowerG version, zone monitoring and configuration can be set up in 
separate tables dedicated to monitoring Motion, Contact, Smoke, Camera, Flood, 
Gas, Hard Wired Devices, and Temperature. 
6.20 Zone Status/Trouble 
This table is applicable to the PowerG models. 
The Zone Status/Trouble screen displays diagnostic information for all zones that 
are set up, equipped, and monitored on the premises. A Yes indication alerts that a 
condition exists that needs checking. A No indication means that the condition is 
normal. 
∗
∗∗
∗
 Available in PowerMaster models only 