User guide
Chapter 6: Data Details Tables 
48  DE5450S Remote Programmer Guide Rev. 9 
6.21 Panel Status/Trouble 
This table is applicable to the PowerG models. 
The Panel Status/Trouble screen displays diagnostic information that is uploaded 
from the Control Panel. 
A Yes indication alerts that a condition exists that needs checking. A No indication 
means that the condition is normal. 
Condition  Description 
STATUS 1/ 
STATUS 2 
Armed/Disarmed, Ready/Not Ready 
LOW BATTERY  Control Panel’s battery needs replacement or 
is not connected. 
NOT ACTIVE  Control Panel is not transmitting. 
FUSE TROUBLE  Fuse has shut the current circuit and will 
reset automatically. 
LINE FAILURE  Telephone line or network (such as GSM) is 
disconnected. 
COMMUNICATION 
FAILURE 
Communication failure between the control 
panel and the monitoring station. 
TAMPER OPEN  Control panel has been opened or tampered 
with. 
JAMMED 
TROUBLE 
Control panel transmissions are being 
jammed. 
TAMPER ALARM  Control panel has been opened or tampered 
with. The alarm. The alarm state ends only 
after disarming and then rearming the 
system. 
OTHERS  Other system faults. 
PROTOCOL 
VERSION 
System’s communication protocol version. 