User Manual

D-302415 1
RP-610 PG2
Wireless Repeater for PowerG Communications
Installation Instructions
1. INTRODUCTION
The RP-610 PG2 is a range extender designed to relay digital data
between wireless PowerMaster-10 Devices and a PowerMaster-10
Control Panel. Repeater links are required when the Control Panel
is beyond the range of at least some of the devices and is therefore
incapable of receiving transmissions directly (see Figure 3).
Figure 1.
External View
2. SPECIFICATIONS
Frequency Band (MHz): Europe: 433, 868, USA: 915
Modulation: GFSK
Antenna: Built-in antenna
Communication Protocol: PowerG
Power Supply:
Type A
AC Power Supply: AC to AC adaptor:
120 VAC, 60 Hz / 9 VAC, 0.35 A min. (in the U.S.A.)
230 VAC, 50 Hz / 9 VAC, 0.35 A min.
Backup Battery
:
4.8-Volt 1300 mAh NiMH rechargeable.
Time to charge: 80 % ( 12 Hrs)
Low voltage alarm: 4.8V
Caution!
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to manufacturer's instructions.
Nominal Current Drain:
Frequency (MHz) 433 868 915
100 mA 100 mA 100 mA
Battery Backup Duration (with fully charged 1300 mA/h
battery): 48 hours.
LED indicator:
Green LED lights when AC power on.
Operating Temperature:
0°C to 49°C (32°F to 120°F).
Humidity:
Average relative humidity of approximate 75% non-
condensing. For 30 days per year relative humidity may vary
between 85 % and 95 % non-condensing.
Dimensions: 161x161x50mm (6-7/16 x 6-7/16 x 1-3/4 in)
Weight: 470g (16.5 oz.)
Compliance with Standards:
Europe: EN 50131-1 Grade 2, Class II, EN 50130-5, EN 50131-
6, EN 301489, EN 50130-4, EN 300 220
USA:
(FCC) CFR47 Part 15
Canada:
RSS210
WARNING!
To comply with FCC RF exposure compliance
requirements, the repeater should be located in a distance of at
least 20 cm from all persons during normal operation. The
antennas used for this product must not be co-located or
operated in conjunction with any other antenna or transmitter.
3. INSTALLATION
3.1 Repeater's Location Selection
A. In a repeater setup, install the repeater where good
communication is assured with the target receiver and with the
transmitters deployed in the repeater's coverage area.
B.
Mount the repeater as high as possible above the floor and
well away from metal chimneys, large metal cabinets, metal
doors and reinforced concrete walls, all of which may reduce
the communication range.
C.
Make sure that the location you have selected is near an
electrical outlet.

Summary of content (5 pages)