Installation Guide

1. Carefully remove all parts from the box.
2. Thread the metal tube (Q) to the center plate (O).
3. Gently set the glass tube (P) to the center plate (O) and secure with lock washer (N)
and lock nut (M) by using wrench (T).Check that the tubes are spaced evenly before
finial tightening.
4. Connect the hot wire (smooth edge,markings) from the arms to the main hot wire
(smooth edge,markings) from the center plate (O) using wire nut (L).
5. Connect the neutral wire (ribbed,no markings) from the arms to the main neutral wire
(ribbed,no markings) from the center plate (O) using wire nut (L).
6. Wrap all connections individually with electrical tape.Double check that all of your
connections are correct.
7. Attach the metal gap (J) and metal tube (I) to the nipple (K) and secure with top loop (H).
8. A 1/4” threaded nipple must be installed in your outlet box.Then install the threaded
nipple (B) into the outlet box.
9. Unscrew the threaded collar on the chain end link (G) and attach it to the top loop (H).
Close the threaded collar to secure the fixture body.
10. Let canopy (D) and lock collar (E) go through the chain (F).
11. With the fixture dimension as a guide, shorten the chain (F) as needed using a pair
of chain pliers.
12. Unscrew the threaded collar on the other chain end link, raise the fixture then attach
chain end link to the ceiling loop (C). Close the threaded collar to secure.
Reverie Medium Single Tier Chandelier
Item # KW 5401
WE RECOMMEND INSTALLATION OF THIS LIGHTING FIXTURE BE DONE BY A
LICENSED ELECTRICIAN.
WARNING***SWITCH OFF THE MAIN ELECTRICAL SUPPLY FROM THE MAIN
FUSE BOX/CIRCUIT BREAKER BEFORE INSTALLATION.
INSPECT ITEM CAREFULLY BEFORE ATTEMPTING TO INSTALL. IF THERE IS ANY
DAMAGE OR OBVIOUS DEFECT. DO NOT INSTALL.
ITEM MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED.
NOTE: CAREFULLY UNPACK EACH PIECE IN TOP LAYER OF PACKING PRIOR TO
REMOVING. RETAIN ALL PACKING MATERIAL UNTIL INSPECTION AND
INSTALLATION ARE FINAL.
DRY
TO assemble safety cables:
1.Join fixture safety cables with safety
cable from ceiling.
2.Wrap both safety cable around the
cable lock nut.
3.Insert screws into both holes on cable
lock nut,secure screws with screwdriver.
4.Push the cable lock nut into outlet box.
Safety cable
Cable lock nut
Ceiling Box
(Not provided)
1/4 IPS threaded nipple pipe

Summary of content (2 pages)