RailCorp Infrastructure Engineering Manual – Signalling 
Maintenance Manual 
Electric Point Machine Westinghouse Style M70 MKIII  TMG E1583 
2.4  Wiring 
The internal wiring is in high temperature PVC insulated wire, 50/02.mm (70/.0076) for 
motor circuits and 30/0.2mm (40/.0076) for control and detection circuits. Wiring 
between the terminal board and the circuit controller is protected by a rigid PVC 
conduit. A 51 mm (inside diameter) flexible conduit connection is provided near the 
terminal board for incoming wires. 
The point machines are wired to short-circuit the detection relay(s) while the detection 
is open. If this is not required, remove the three links between 9-8 and 9-4, 9-4 and 8-
3, 8-3 and 8-7 on the detector switches. 
The internal wiring diagram for the point machine is given in Figure 2.4. 
Version 1.0  © RailCorp 2009  Page 15 of 52 
Issue Date: 1 December 2009  Uncontrolled when Printed 