Specifications
RailCorp Infrastructure Engineering Manual – Signalling 
Maintenance Manual 
Electric Point Machine Westinghouse Style M70 MKIII  TMG E1583 
7  Diagnostic Fault Finding Charts 
7.1  Fault Finding Chart 1 - Point Machine Not Operating 
Fault 
Most Likely 
Emergency 
Subsequent 
Causes 
Action 
Action 
Point machine does not 
operate when control 
circuit is energised 
Internal contactor or N 
or R relay not operating 
Mechanism damaged or 
jammed due to impact 
Points obstructed 
Check control circuitry. 
Replace control relay or 
contactor if necessary 
If practical repair 
damage. If not, replace 
machine 
Overload timer is 
defective 
Remove blockage 
Local wiring to 
mechanism is defective 
Defective points motor 
Supply failure or loose 
terminations in internal 
wiring 
Return relay(s) and/or 
contactor to workshop 
for repair 
Faulty toggle 
mechanism or 
associated motor 
control switch(s) 
Bridge timer contacts 
Test motor operating 
circuits to mechanism. If 
defective run temporary 
wiring 
Check brushes or 
replace motor if 
necessary 
Check supply source 
and fuses. Clean and 
tighten terminations 
Check toggle action and 
replace components or 
switch(s) as required 
Refurbish damaged 
machine if economically 
justified. If not, 
cannibalise for parts 
Replace timer 
Replace defective 
wiring 
Return defective motor 
to workshops for 
overhaul 
Version 1.0  © RailCorp 2009  Page 49 of 52 
Issue Date: 1 December 2009  Uncontrolled when Printed 