Specifications
RailCorp Infrastructure Engineering Manual – Signalling 
Maintenance Manual 
Electric Point Machine Westinghouse Style M70 MKIII  TMG E1583 
7.4  Fault Finding Chart 4 - Point Machine Operates but Detection Fails 
Most Likely 
Emergency 
Subsequent 
Fault 
Causes 
Action 
Action 
Detector slides or rods 
damaged 
Point machine operates 
but detection fails 
Detector slides out of 
adjustment 
Internal linkage 
damaged or displaced 
Replace detector slides 
Re-adjust detector 
slides in accordance 
with appropriate 
procedures 
Faulty detection 
switch(s) 
Re-align or replace 
linkage and re-adjust 
circuit controller 
Loose connections in 
circuit controller wiring 
Replace faulty switch(s) 
Clean and tighten 
terminations 
Version 1.0  © RailCorp 2009  Page 52 of 52 
Issue Date: 1 December 2009  Uncontrolled when Printed 