TM Deluxe U -1 3 0 Manufactured by DM Industries, Ltd.
TA B L E O F C O N T E N T S Owner’s Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This OWNER’S MANUAL has been designed to familiarize you with your Spa operations and general maintenance. We suggest that you take some time to carefully review it. Please keep this manual available for reference. If you have any questions regarding your spa set-up, operation or maintenance, please contact DM Technical Support at the numbers below.
IMPORTANT SAFETY INSTRUCTIONS WHEN INSTALLING AND USING THIS ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: 1. WARNING : To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times. 2. DANGER! RISK OF ACCIDENTAL DROWNING. Extreme caution must be exercised to prevent unauthorized access by children.
C. Before entering a spa, the user should measure the water temperature with an accurate thermometer, since the tolerances of water temperature regulating devices vary. D. The use of alcohol, drugs, or medication, before or during spa use, may lead to unconsciousness with the possibility of drowning. E. Persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, circulation system problems, or diabetes should consult a physician before using a spa. F.
WARNINGS Prolonged immersion in water that is warmer than normal body temperature can result in a dangerous condition known as HYPOTHERMIA. The causes, symptoms, and effects of hypothermia may be described as follows: Hypothermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6 degrees F. The symptoms of hypothermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of the body.
INSTALLATION INSTRUCTIONS Site Selection/Preparation The spa must be installed on a structurally strong, solid and reasonably level surface. The site should allow for drainage away from the equipment compartment in which the electrical components are housed. Take into account the following when considering prospective sites: LOCAL CODES: There may be certain restrictions and/or requirements that are particular to your locality. DELIVERY PASSAGEWAY: Doors, halls, stairs, etc.
Spa Location 1 6 2 3 4 5 CLEARANCES CHECK THE FOLLOWING AREAS PRIOR TO SPA DELIVERY 1. STEPS - We suggest no more than six without a landing. 2. TREE BRANCHES - Clearance for spa passage. 3. TIGHT CORNERS - Make sure there is space to maneuver. 4. STORAGE SHEDS, DOG HOUSES, WOOD PILES - Remove out of the way. 5.GATES:CLEARANCE FOR PASSAGE OF SPA - Does gate need to be removed from hinges? 6. OVERHANGS AND GUTTERS - Anything overhead, as well as drain pipe locations, must allow for spa passage.
ELECTRICAL REQUIREMENTS AND INSTALLATION WIRE YOUR SPA PER ONE OF THE DIAGRAMS MOST SIMILAR TO YOUR HOUSE PANEL ALL WIRES FEEDING THE SPA ARE TO BE THE SAME GAUGE. GROUND WIRES ARE TO BE INSULATED AS WELL. WHEN USING A GROUND ROD, THE GROUND WIRE TO THE ROD SHOULD BE #6 BARE COPPER. ALL SPAS REQUIRE THE USE OF AN ISOLATED GFCI PROTECTED CIRCUIT. THE INSTALLATION OF A DISCONNECT IS REQUIRED NO MORE THAN TEN (10) VISUAL FEET FROM THE SPA AND NOT LESS THAN FIVE (5) FEET.
SEPARATE NEUTRAL & WEAK GROUND OR ROMEX WIRE USED TO FEED GFCI WITH UNDERSIZED GROUND WIRE COMMON NEUTRAL GROUND BAR IN MAIN —8—
GFCI IN PANEL WITH COMMON NEUTRAL BAR AND/OR ROMEX WITH UNDERSIZED WIRE USED TO FEED DISCONNECT.
GFCI MOUNTED IN PANEL AND DISCONNECT MOUNTED INSIDE TO COMMON WALL WITH METAL STUDS OR WITH METAL MOUNTING BOX.
ALL WIRING TO THE SPA SHOULD BE IN ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES. ALL WIRING SHOULD BE PERFORMED BY A LICENSED ELECTRICIAN KNOWLEDGEABLE IN THE OPERATION AND WIRING OF A GFCI PROTECTED SYSTEM. 1. The spa must be permanently connected (hardwired) to the power supply. No extension cords or plug-type connections are to be used in conjunction with the operation of the spa.
Getting Started: NOTE: For best results, read each step carefully and entirely before proceeding to the next. FILL YOUR SPA Wipe the interior of the spa with a damp, soft cloth to remove any residue that may be on the surface. Fill with a garden hose. As the spa is filling check in the equipment access area for any leaks. On occasion, it may be necessary to hand tighten a union fitting that may have come loose during transit.
CONTROLS & OPERATING INSTRUCTIONS Note: For best results, read each step carefully and entirely before proceeding to the next. TESTING THE GFCI The GFCI shuts off the electricity in a fraction of a second if there is ashort anywhere in the system. It is recommended that the GFCI be tested prior to each use. Test as follows: 1. Push the TEST button on the GFCI. The RESET button with trip out, the topside digital control LED display with go out. If this does not happen, DO NOT USE SPA.
D. Auto Heat Operation This equipment has includes a 2-speed pump for the primary pump. The low speed operates during filtration and heating cycles. Your selected water temperature will be maintained automatically 24 hours a day. The electronic thermostat will monitor your water temperature at the top of each hour by cycling the low speed pump for 2 minutes. If the water temperature reaches the set temperature, at which point both low speed pump and heater will turn off.
J. Resetting Your Spa Just like your computer at home, you spa electronics could get corrupted by electrical surges or spikes, or by low voltage. This could result in improper operation. Anytime there is reason to believe that your system is not operating properly, please follow the following resetting procedure: 1.Turn the power to the off for 15 full minutes 2.Turn the power back on. 3. Press “PROG” to show time. 4. Press and hold the “UP” arrow for 5 seconds. The control display will show 12:00 p.m.
SPA MAINTENANCE Your spa is manufactured with the highest quality and most durable materials available. A spa care and maintenance program is recommended to increase your comfort, maintain the spa’s reliability and protect your investment. 1) DRAINING YOUR SPA Detergent residues from bathing suits as well as soap film from your body may gradually accumulate in the water. Foam inhibitors will suppress the foam but will not remove the soap from the water.
3) FILTER MAINTENANCE Maintenance is the most critical factor in keeping your spa water clean. To clean the filter: NEVER RUN SPA WITHOUT FILTER A. Remove the cartridge and spray it with a garden hose. It will be necessary to rotate the cartridge while spraying so as to thoroughly remove the debris lodged between the filter pleats. B. After allowing to dry, inspect the cartridge for calcium deposit (scaling) or an oil film.
WATER QUALITY AND MAINTENANCE GENERAL GUIDELINES FOR WATER QUALITY MAINTENANCE Maintaining water quality within specific limits will enhance your enjoyment and prolong the life of the spa. Safe, comfortable and clean spa water is a fairly simple task to achieve, but it does require regular attention because of the numerous factors that can alter it. There is no one formula to be followed because of the variables, i.e. quality of the water used to fill the spa, water temperature user load, etc.
DIAGNOSTIC & TROUBLESHOOTING Resetting Your Spa Just like your computer at home, you spa electronics could get corrupted by electrical surges and operate improperly. If your spa system is not operating properly or shows any of the following messages, please reset it to see if the malfunction clears itself. Turn power off for 15 full minutes – then – turn power back on – then- press “PROG” to show time_then_Hold “UP” for 5 seconds. Display will show 12:00p.m., indicating a successful reset (reboot).
Maintenance Record Keep track of your water maintenance — 21 —
Heater Terminal Block Transformer Pressure Switch Circuit Board Schematic U130 — 20 —
LIMITED WARRANTY FOR ECO SPAS DM Industries, Ltd., extends this limited warranty solely to the original Purchaser of any Eco Spa purchased within the United States or Canada. 5 YEAR STRUCTURAL SPA SHELL: DM Industries, Ltd., warrants its shells against loss of water due to defects in materials and workmanship for five (5) years from the original date of purchase.
© 2005 DM Industries Ltd 2320 NW 147th Street Miami, Florida 33054 PH 305-685-5739 ECODX-05-0517