Operating instructions

11
VITA SPA DUET
To clean the jet insert and housing, use a
pressurized hose and spray the inside of
the jet housing. Soak the jet in a diluted spa
cleaning solution, rinse. Wipe the inside of the
housing to remove any debris.
To reinstall the jet, line up the tab on the
backside of the barrel with the groove in the
body. Use the palm of your hand to gently tap
the jet until it snaps into position.
Air Control
The intensity of the jet action can be
controlled by altering the amount of air
injected with water through the jets. Your
spa has 1 air control located on the lip of
the spa. Each control activates air to speci c
jets in the spa allowing you to create various
combinations and levels of jet action to
suit individual preferences. Turn the control
counter- clockwise to turn the air o and
clockwise to turn air on.
NOTE: Air controls should be closed
during heating cycles for maximum
energy e ciency.
Diverter Valve: Diverts water from one set
of jets to another. The diverter valve should
be tested weekly to clean the lines and to
help prevent debris from building up.
NOTE: The diverter valve should be cleaned
regurally. Remove the handle by pulling
upward and rocking it back and forth,
unscrew the cap and pull the valve stem out.
To clean the valve stem and housing, use a
pressurized hose and spray the inside of the
valve housing. Soak the valve stem in a diluted
spa cleaning solution, rinse. Wipe the inside of
the housing to remove any debris.