Operating instructions

25
VITA SPA DUET
Message Meaning What Happens… Possible Causes Action Required
No message on
Display Power
has been cut
o to the spa
Verify power going to
spa. Check for tripped
breaker or blown fuse.
The control panel will
be disabled until pow-
er returns. Spa setting
will be preserved until
the next power up.
HH “Overheat”
- *One of the
sensors has
detected 118F
/ 47.8C at the
heater
The spa will shut
down and will
automatically
reset once the
water tempature
has cooled to 108F
(42C)
~ L o w W a t e r F l o w
~ Faulty Equip-
ment
DO NOT ENTER THE
WATER. Remove the
spa cover and allow
water to cool. ~
Verify all slice valves
are locked open ~
Verify Actual water
tempature with a
digital Thermom-
eter ~ Verify normal
operation of pump 1
~ Verify all spa jets are
open. Once the heater
has cooled, reset by
pushing any button. If
the spa does not reset,
shut o the power
to the spa and call
your dealer or service
organization.
* - Even when the spa is shut down, some equipment will turn on if freeze protection is needed.
COMMON PANEL MESSAGES
Message... What it is... What it means...
Pr Priming mode Spa is in normal Priming Mode operation
SL Sleep mode Spa is in normal Sleep Mode operation
EC Economy mode Spa is in normal Economy Mode operation
ST Standard mode Spa is in normal Standard Mode operation
IC Freeze condition Heater will come on to keep water above 45°F
- - Water temperature Current water temperature not measured