Operating instructions

27
VITA SPA DUET
Message Meaning What Happens… Possible Causes Action Required
Sn Sensors are out
of balance.
If alternating with
spa temperature,
it may just be a
temporary condi-
tion. If  ashing by
it itself, spa is shut
down*
May appear tem-
porarily in an over
heat or freeze
condition
If the problem persists,
contact your dealer or
service organization.
May appear temporar-
ily in an over heat or
freeze condition
HL A signi cant
di erence
between tem-
perature sen-
sors has been
detected. This
could indicate a
ow problem
Heater will shut
down while spa
continues to func-
tion normally
~ Low water level
~ Dirty spa  lter(s)
~ Closed spa jets
Verify water level is
within 1/8” from top of
weir door - make sure
all jets are open, all
pumps are operating
normally and the spa
lter(s) are clean. If
the problem persists
contact your dealer or
service organization
LF Persistent low
ow problems.
(Displays on the
fth occurrence
of HL mes-
sage within 24
hours) Heater is
shut down, but
other spa func-
tions continue
to run normally
Heater will shut
down while spa
continues to func-
tion normally
~ Low water level
~ Dirty spa
lter(s)
~ Closed spa jets
Follow action required
for HL message.
Heating capability of
the spa will not reset
automatically; you
may press any button
to reset.
dr Lack of water
owing
through the
heater
Spa is shut down
for 15 minutes
Low water Level,
poor  ow, or air
bubbles detected
in the heater.
Verify water level is
within 1/8” from top of
weir door - make sure
all jets are open, all
pumps are operat-
ing normally and the
spa  lter(s) are clean.
Spa will reset in 15
minutes, if the prob-
lem persists contact
your dealer or service
organization