Owner`s manual

PAGE 25
A. AUTO M ATIC BLOWER AND JET PUR G E
Twice each day, at 10AM and 6PM,
the blower and jet pump(s) will automatically
run for one minute to circulate potential stale
water in the piping. This is a normal function
of the spa. “ B J 2 P ” will be displayed while this
takes place.
B. ME M O RY
All settings that are entered into your spa
controller will be permanently retained in its
solid state memory. In the event of a power
failure, the time will be captured and held until
power returns. All settings existing at the time
of the power failure will be restored when
power returns.
C. FAC TO RY SETT IN GS
To reset to factory settings, do as follows:
1. Turn off the power breaker to the spa for
five minutes.
2. Turn breaker on
3. Hold down the “ V IE W ” button for 10 sec-
onds. ” 1 2 : 0 0 ” will be displayed and all
previous settings will be lost other than
temperature ”10 2 º F.” Time, day, and heat days
will have to be programmed into the system.
D. PA N E L L O C K
The Selectron Plus spa panel can be locked to
keep children or others from using any of the
spa functions. To deactivate all buttons, make
sure “ T IME ” is displayed. Use “ V I E W ” b u t t o n
to change to “ T IME ” display if needed. Th e n
hold the “ UP” arrow button for 5 seconds.
Notice the flashing lock icon. The panel is
locked. To unlock the panel, hold the “ UP ”
arrow button for 5 seconds again. The flashing
lock icon will disappear and all spa functions
will be accessible.
E. HE ATER LO C K
You may want to prevent anyone from
c h a n ging the water temperature you have
chosen, while still allowing the use of any of
the spa functions. This can be accomplished
from the “ PA NEL LOCK” position only.
Follow the “ PA N EL L O C K ” procedures first
and then, with the lock icon flashing, hold
down the “ D OW N ” arrow for 5 seconds. Th e
lock icon will be present but not flashing. All
other spa functions will still operate. To
unlock the “ HE ATER LOCK” and “ PA NE L
LOCK” hold down the “ UP ” arrow button for
5 seconds. The lock icon will disappear and
all spa functions, including temperature
adjustment will be accessible.
F. FREEZE PROTECTION
If the temperature in the spa plumbing falls
below 50º Fahrenheit (10º Celsius) the water
pump(s) will turn on soft-mode and run for at
least one minute. The display will show “ I C E ”.
After one minute, if the water is still below 50 º
F (10º Celsius), the heater will turn on and
raise the water temperature 10º F.
G. FLOW PROTECTION
If the flow of water through the heater is
insufficient, the spa controller will
automatically turn the heater off to prevent
overheating. Call for service if you cannot
pinpoint the cause.
H. OVERHEAT PROTECTION
If the water temperature inside the spa
reaches 112º F, the pumps and the heater will
be disabled. If the water temperature
continues to rise and reaches 118º F due to
friction in the pumps and plumbing system,
the entire system including all pumps will be
disabled. In “ H I L I ” condition, DO NOT
ENTER THE WATER! Remove the cover and
allow the water temperature to cool down to
104 degrees F. Then run diagnostic by
pressing the “PROG” button 3 times. If the
“HILI” message returns, call for service.