Owner`s manual

PAGE S-4
OPERATING INSTRUCTIONS
ADVANCED FEATURES SETUP
Note that at any point in the sequence, press any
other button to exit programming. Alternately, the
display will return to normal if no button is pressed
within 10 seconds.
SETUP ("SU")
Enter programming menu by holding "PROG"
button for 5 seconds. Then press "PROG" to
sequence to "SU" on the display. To access the
advances features menu, while in the "SU" display,
hold the "PROG" button for 10 seconds.
PUMP SETUP
Your spa is factory programmed in accordance with
the spa model for the number of pumps it offers.To
ensure that pump setting is correct or to change it
if needed, press "PROG" to sequence to "P= XX.
Use UP/DOWN buttons to select the number of
pumps installed. (Note: that the "C" following each
number designates the inclusion of a circulation
pump).
P=3C or 2C or 1C - (3, or 2 or 1 therapy pump plus
circulation pump)
P=3 or 2 or 1 - (3, or 2, or 1 therapy pump)
SETTING THE SERVICE AMPERAGE DRAW
While in "SU" programming menu, press "PROG" to
sequence to S=3 on the display.
S=3" is the factory default. Use the "UP" or
"DOWN" arrows to change the pump setting:
S=3 Indicates that the heater will shut off if four
pumps are on high speed. (The blower-air pump is
included in the count.
S=2 Indicates that the heater will shut off if three
pumps are on high speed at the same time.
S=1 Indicates that the heater will shut off if two
pumps are turned on high speed at the same time.
S=0 Indicates that the heater will shut off if one pump
is turned on high speed.
Service level S=0 is only setting for 120v 60Hz and
230V 3 phase 50Hz spas.
Once the service level has been set, it does not
have to be set each time. It will be entered into the
system memory.
BLOWER AND JET PURGE
For the self-test function to work properly, the
blower setting must be set correctly: "b=b" if there
is a blower & "b= -" if there is no blower. If the
blower setting is incorrect, while in "SU"
programming mode, press "PROG" to sequence to
"b=b" or "b=-". Use UP/DOWN buttons to select
the correct setting.
Each day, at 10am and 6pm, the blower and jet
pump(s) will automatically run for one minute to
circulate potential stale water in the piping.This is a
normal function of the spa. "BJ2P" will be displayed
while this takes place.
Note: Spa will skip sequence if any other function is
operating.
PRIMING
Normal setting is "Pr=P" This indicates that all
pumps will turn on for 2 minutes to insure proper
priming when the spa is powered up, initially or
after power interruption.This setting should remain
in that mode.